============================================================================== Station Notes - Bear Lake: 09/01/2020: Station Retired [1100] - station retired due to relocation - new replacement station: onekama (obl) 06/03/2020: Station Maintenance: [1345] - routine maintenance - replaced wind sentry (wind speed / wind direction) - reinstalled soil temperature sensor (2", SOIL0) ============================================================================== 08/22/2019: Logger / Station Maintenance: [1330] - replaced logger (CR10X -> CR1000) - added PakBus modem - loaded logger program: blk-bbac ============================================================================== 08/22/2018: Station Maintenance: [1200] - annual station / site maintenance 06/25/2018: Station Maintenance: [1400] - annual station / site maintenance ============================================================================== 12/19/2017: Station Maintenance: [1100] - replaced faulty logger battery (35 amp battery installed) - installed 10W solar panel 11/21/2017: Station Maintenance: [1940] - replaced logger battery 07/17/2017: Station Maintenance: [1405] - annual maintenance 02/16/2017: Station Maintenance: [1100] - replaced logger battery ============================================================================== 12/14/2016: Station Maintenance: [0830] - replaced logger battery 07/01/2016: Station Maintenance: [1215] - annual maintenance and weed removal - replaced both soil temperature sensors (2", 4") 01/23/2016: Station Maintenance: [1900] - replaced faulty battery ============================================================================== 12/20/2015: Station Maintenance: [1050] - replaced faulty battery 11/20/2015: Station Maintenance: [1300] - replaced faulty anemometer (wind speed) 05/04/2015: Station Maintenance: [1500] - replaced faulty 2" Soil Temperature (SOIL0) sensor 03/06/2015: Station Maintenance: [0003] - loaded logger program "mawn_abcf" (hourly collection cycle) ============================================================================== 12/09/2014: Station Maintenance: [0009] - Loaded Logger Program "mawn_abcw" (3-hour collection cycle) 12/07/2014: Station Maintenance: [0815] - replaced failing logger battery 10/23/2014: System Maintenance: [0904] - moved data-collection to new LoggerNet server - loaded logger program "mawn-abcf" 09/03/2014: Station Maintenance: [1545] - Replaced 2" soil temperature sensor (SOIL0) 06/27/2014: Station Maintenance: [1500] - Replaced tipping-bucket rain gauge 02/25/2014: Station Maintenance: [0003] - Loaded Logger Program "ABCF" (hourly collection cycle) ============================================================================== 12/18/2013: Station Maintenance: [1323] - Loaded Logger Program "ABCW" (3-hour collection cycle) 12/15/2013: Station Maintenance: [1155] - Replaced logger battery. - Battery issues led to recent data loss. ============================================================================== 09/24/2012: Station Maintenance: [1620] - Repaired tipping-bucket rain gauge, replaced funnel. - Due to failure, precipitation data was lost during the following time period: 09/07/2012 [d=251] 00:05 - 09/24/2012 [d=268] 16:25 03/03/2012: Station Maintenance: [0003] - Loaded MAWN Program - ABCF (hourly collection cycle) ============================================================================== 12/14/2011: Station Maintenance: [0003] - MAWN Program "ABCW" loaded: - 3-hour power/collection cycle - soil moisture data back online 11/27/2011: Station Maintenance: [1230] - Soil Moisture probes replaced (CS615 to CS616). - Before soil moisture data is recorded, MAWN program will need to be updated. 07/13/2011: Station Maintenance: [1200] - Site visit to correct recent communication trouble. - As of 07/13/2011 1400, station back online. However, data recorded during the following time period was lost due to the outage: 06/22/2011 (d=173) 0405 - 06/25/2011 (d=176) 1800 03/02/2011: Station Maintenance: [0003] - Loaded MAWN Program - AACF (hourly collection cycle) ============================================================================== 12/08/2010: Station Maintenance: [0002] - Loaded MAWN Program - AACW (3-hour collection cycle) 03/11/2010: Station Maintenance: - Loaded MAWN Program - AACW (3-hour collection cycle) [0008] ============================================================================== 12/09/2009: Station Maintenance: - Loaded MAWN Program - AACW (3-hour collection cycle) [0105] 03/01/2009: Station Maintenance: - Loaded MAWN Program - AACF (hourly power cycle) [0003] ============================================================================== 11/23/2008: Station Maintenance: - Loaded MAWN Program - AACW (3-hour power cycle) [0005] 10/28/2008: Station Maintenance: - Loaded MAWN Program - AACF (60-minute power cycle) [0004] 05/14/2008: Station Maintenance (sm): - Communication converted to broadband cell-modem: - Broadband cell-ip modem installed - Datalogger progam "mawn_aacs" loaded and compiled. - Battery voltage now reported every hour. - Data collection configured to upload every 30 minutes. - General station maintenance and system checks, including: - Soil Moisture sensors now installed vertically: - MSTR 0: profile of depth = 0 - 12" - MSTR 1: profile of depth = 12 - 24" - Work was done approx: 14:00 (Day=135) ============================================================================== 10/11/2005: Quality Control (jtb): - Faulty Wind Speed Data (see note from 10/05/2005 below) was removed from the MAWN database. Wind Speed collected during the following time period was marked as "missing". From: 08/20/2004 (Day=233) 9:50 To: 10/05/2005 (Day=278) 10:55 10/05/2005: Station Maintenance (sm): - Replaced anemometer (10:30am). This sensor had been out of service since 08/20/2004. - Tightened wires for Soil Moisture B - were extremely loose which may have lead to some missing data. - Power leads to CR10X from battery were also very loose. These have also been tightened. - Checked all sensors. - Routine maintenance and cleaning. ============================================================================== 07/17/2004: Station Maintenance: (jal) - Soil Moisture leads connected to the datalogger were cleaned up. No sensors were replaced. ============================================================================== 05/08/2002: Phone Line Activated and Data Collection Started: Phone Number: (see setup notes) - Archived data set should be setup to ensure that the first day of record is complete. To do so, use the following as the start of the the data archive: 24 hour data: 24:00, Day=127 (05/07/2002) 60 min data: 01:00, Day=127 (05/07/2002) 05 min data: 00:05, Day=127 (05/07/2002) 05/06/2002: Station Installed (jaa, crn): - Leaf Wetness A: Installed on NE tripod leg (fence post). It is 35-inches from the ground to the center of the wetness grid. May need to install on a standard mount - did not have all of the necessary components (see below). - Leaf Wetness B: Connected to datalogger, but not yet placed in canopy. - Soil Temps: Installed under bare ground. SW quadrant, near foot of tripod leg: Sensor A: 2-inch depth Sensor B: 4-inch depth - Soil Moistures: Installed horizontally nder sod. SE qudrant, near foot of tripod leg. Sensor A: 10-cm depth Sensor B: 25-cm depth - Air Temp/RH: HMP45C (requires mawn1b). Installation height approx. 59" to 8th ring of radiation shield - Wind Vane: Points to North - Anemometer: Points to South - Pyranometer: Stand mounted to SW. Mounted high enough to keep shadow from solar panel from falling on plate (e.g. bottom of bracket should be approx. 39" above tripod bracket. - Solar Panel: Installed near the top of the mast, bracket sits approx. six inches below coupling at the top of the mast. The top edge of the solar panel must not exceed height of the Pryanomter. Solar panel faces south with an angle of about 44-degrees - Precipitation: Tipping bucket rain guage. Mounted on NW tripod leg (fence post). Approx. 1 meter (39.73") to top of rain guage. - Phone Line: Junction Box installed at the end of the NE tripod leg. Phone line not yet available. - Modem: Wired follows: red -> ring green -> tip - GPS Coordinates Estimated: Lat: 44.3719 N Lon: -86.1627 W Alt: --- - Needs: - Leaf Wetness A may need a mounting block (including the necessary mounting pipe, block, and u-bolts). - Leaf Wetness B needs to be placed in canopy of choice. - GPS Coordinates Need to be taken. - Site/Station photos. - Comments: - Herbicide applied over soil temperatures (SW quadrant). ==============================================================================