============================================================================== Station Notes - Constantine (Pioneer Production Plant) 06/04/2026: Station Maintnenace: [1055] - sensor repair / replacement: - replaced atmp/relh radiation shield - replaced atmp/relh sensor (HMP45 -> HygroVue10) - upgraded logger program: cnt-bbsd.cr1 (11:12 EDT) =============================================================================== 05/18/2023: Station Maintenance: [1430] - routine station maintenance, including: - checked anemometer (bearings good) - checked atmp/relh sensor and radiation shield (good) - checked battery (13.36V) - checked pyranometer (good) - checked soil sensor cables (good)** - checked solar panel (19.49V) - checked tipping-bucket rain gauge (adjusted level) - cleaned solar panel - tested leaf wetness sensor [standard] (good)* * site does not include a canopy sensor ** reinstalled soil temperature probe [5cm] 04/27/2023: Station Maintenance: [1105] - routine site maintenance, including: - checked anemometer (good) - checked battery (13.67 V) - checked pyranometer (adjusted level) - checked soil sensor cables (good) - checked solar panel (20.21 V) - checked wind vane (properly aligned) - checked / cleaned tipping-bucket rain gauge (adjusted level) - checked / tested leaf wetness [standard] (good)* - cleaned solar panel * site does not include a canopy leaf wetness sensor =============================================================================== 08/02/2022: Station Maintenance: [1235] - site maintenance, including: - replaced faulty leaf wetness sensor [standard] 07/13/2022: Station Maintenance: [1030] - routine site maintenance, including: - checked anemometer (bearings good) - checked battery (13.46 V) - checked pyranometer (good) - checked soil sensor cables (good) - checked solar panel (17.96 V) - checked wind vane (properly aligned) - checked / cleaned tipping-bucket rain gauge - checked / tested leaf wetness [standard] (good)* - cleaned atmp/relh sensor and radiation shield - cleaned solar panel * site does not include a canopy leaf wetness sensor 06/06/2022: Station Maintenance: [1200] - routine site maintenance, including: - checked anemometer (bearings sound good) - checked pyranometer (good... level) - checked soil sensor cables (good) - checked tipping-bucket rain gauge - checked wind vane (properly aligned) - checked / tested battery (good) - checked / tested leaf wetness (standard... good)* - cleaned solar panel - weed removal (not needed) * site does not include a canopy leaf wetness sensor ============================================================================== 07/14/2021: Logger Maintenance: [1107] - loaded logger program: cnt-bbad.cr1* - wind direction fix * supports "maintenance mode" 07/12/2021: Station Maintenance: [1005] - routine site maintenance 05/25/2021: Logger / Station Maintenance: [1120] - routine site maintenance - updated modem 05/05/2021: Logger / Station Maintnenace: [1300] - loaded logger program: cnt-bbad.cr1 (237 -> LWS-L)* * sensor replaced: 08/11/2020 (no canopy) - cleaned-up previously collected data ============================================================================== 08/11/2020: Logger / Station Maintenance: [1315] - replaced leaf wetness (237 -> LWS-L) [no canopy] - requires logger program change ============================================================================== 05/26/2020: Station Maintenance: [1345] - routine maintenance - reinstalled soil moisture sensors 04/27/2020: Station Maintenance: [1055] - station relocated (1400-ft south) - pyranometer (solar radiation) [LI200X] - wind sentry (wind speed / direction) replaced - no logger program change needed ============================================================================== 08/12/2019: Logger / Station Maintenance: [1115] - replaced logger (CR10X -> CR1000) - added PakBus modem - loaded logger program: cnt-bbac 07/11/2018: Station Maintenance: [1510] - routine station / site maintenance 05/07/2018: Station Maintenance: [1215] - annual station / site maintenance ============================================================================== 10/17/2017: Station Maintenance: [1700] - repair communication issues: - replaced SC932A interface cable 07/19/2017: Station Maintenance: [1305] - annual maintenance 05/19/2017: Station Maintenance: [1430] - annual maintenance ============================================================================== 07/26/2016: Station Maintenance: [1155] - annual maintenance and weed removal 06/07/2016: Station Maintenance: [1245] - replaced battery - replaced faulty soil moisture sensor wiring 06/06/2016: Station Maintenance: [1422] - replaced faulty battery - installed additional solar panel 05/11/2016: Station Maintenance: [1100] - routine maintenance, including: - replacement of leaf wetness (LWS) sensors - weed removal 01/06/2016: Station Maintenance: [1230] - replaced faulty battery - replaced faulty TEMP/RH sensor (HMP45C) ============================================================================== 12/27/2015: Station Maintenance: [1700] - battery replaced 07/15/2015: Station Maintenance: [1300] - Soil Temp (2") Sensor checked and reinstalled 05/20/2015: Station Maintenance: [1200] - routine maintenance, including: - replacement of anemometer cups - adjustment of tipping-bucket rain gauge - weed removal 02/24/2015: Station Maintenance: [0005] - loaded logger program "mawn_abcf" (hourly collection cycle) ============================================================================== 12/13/2014: System Maintenance: [0005] - loaded logger program "mawn_abcw" 12/10/2014: Station Maintenance: [1115] - faulty battery replaced 11/12/2014: System Maintenance: [1505] - moved data-collection to new LoggerNet server - loaded logger program "mawn_abcf" 08/06/2014: Station Maintenance: [0000] - Corrected irrigation system (introduced faulty data for 07/24/2014) 02/25/2014: Station Maintenance: [0005] - Loaded Logger Program "ABCF" (hourly collection cycle) ============================================================================== 12/17/2013: Station Maintenance: [1430] - Logger battery replaced. 12/15/2013: Station Maintenance: [0004] - Loaded Logger Program "ABCW" (3-hour collection cycle) ============================================================================== 12/17/2012: Station Maintenance [1357] - Replaced Battery. Battery issues led to recent data loss 06/15/2012: Station Maintenance: [1330] - Removed Blockage from Rain Gauge - Replaced Modem - Provide Updated GPS Info: LAT: 41.8277 LON: -85.6616 ============================================================================== 05/21/2010: Station Maintenance: [1330] - General station maintenance (weed control, sensor checks) ============================================================================== 10/28/2008: Station Maintenance: - Loaded MAWN Program - ABCF (60-minute power cycle) [0006] 07/23/2008: Station Maintenance: - General station maintenance and system checks, including: - Replaced datalogger: - Faulty logger caused loss of data for the following time period: 07/21/08 (d=203) 16:25 - 07/23/08 (d=205) 10:00 - Loaded MAWN Program ABCS (30-minute power cycle) - Soil Moisture sensors now installed vertically: - MSTR 0: profile of depth = 0 - 12" - MSTR 1: profile of depth = 12 - 24" - Work was done approx: 0950 - 1015 (Day=205) ============================================================================== 11/19/2007: Station Maintenance (jb): - Loaded MAWN Program: MAWN_ABCF (1-hr power cycle) [13:07] 08/15/2007: Station Maintenance: (bn): - Communication converted to broadband cell-modem: - Broadband Cell modem installed. - Datalogger Program "mawn_abcs" Loaded and Compiled - Data Collection Configured To Upload Every 30 minutes. - General Station Maintenance and System Checks: - Work was done approx: 16:45 - 17:05 (Day=227) ============================================================================== 05/31/2006: Station Maintenance: (bn): - General Station Maintenance and System Checks: - weed removal and application of Round-Up above soil temps - sensor placement checked - anemometer bearings checked - rain gauge checked for debris - leaf wetness A (standard mount) - missing screw was replaced. - Work was done approx: 15:10 - 15:40 (Day=151) 05/22/2006: Station Maintenance (sm): - The datalogger for the Constantine MAWN station malfunctioned over the weekend. The reason for the failure is unknown, but this morning, the data collection program (mawn1c) needed to be reinstalled (uploaded). This was done at 9:00am and once again, data is being recorded. However, the recent troubles did lead to a loss of data - there is no data for the Constantine MAWN station during the following time period: 05/20/06 05:10 - 05/22/06 09:00 =============================================================================== 08/16/2004: Station Maintenance: (jal): - General Station Maintenance and System Checks: - weed removal and application of Round-Up above soil temps - tipping bucket rain guage checked for accuracy - Work was done approx: 14:40 - 14:45 (Day=229) 09/17/2004: Data Correction (jtb): - Faulty Solar Radiation Data Marked As Missing For the Following Data Entries: 06/28/04 (Day=180) 00:05 - 08/19/04 (Day=232) 24:00 08/19/2004: Station Maintenance (jal): - Replaced Pyranometer (Solar Radiation Sensor) 04/14/2004: Data Logger Maintenance (crn, sm): - Faulty CR10X Datalogger temporarily replaced with CR10. Will be replaced with a new CR10X after next hardware order. (approx 11:30am). - Lightning Surge Protection Upgraded. 04/07/2004: Data Logger Maintenance (jtb): - Datalogger error (E08) codes were reading 99. Counters were reset back to 00. This action will hopefully resolve and/or prevent brief data outages observed on some data loggers when the error count reaches 99. 01/02/2004: Station Repair (crn) - Incomplete data collection over the past several weeks led to replacement of the data logger. Tests indicate the power supply is fine. Data logger was replaced around 12:00pm. - Replaced the following: Data Logger (CR10X): Serial #: X ????? - Data between the following dates is incomplete and Daily values may be inaccurate due to gaps in data: Dec 22, 2003 (Day=356) thru Feb 02, 2004 (Day=002) 04/30/2003: New Station Installed: Notes: - tripod legs need to be bolted to fence posts - leaf wetness A needs to be properly mounted - soil moisture A & B not reading properly 05/01/2003: Data Collection and Data Archive for new station begins First report: May 1, 2003 - 00:05 (Day=121) 05/06/2003: System Maintenance: - New Datalogger Program Loaded (MAWN1C) at 17:45. (change made to enable recording of CS616 soil moisture probes) ==============================================================================