=============================================================================== Station Notes - Deerfield / Blissfield (MI) 10/09/2025: Logger Maintenance: [1049] - loaded logger program: drf-bbsdS.cr1* * supports HMP155A -> HygroVue10 change (atmp/relh) ============================================================================== 03/19/2023: Logger / Station Maintenance: [1015] - resolved communication issue: - reconnected ground wire - replaced modem - routine site maintenance, including: - checked anemometer (bearings good) - checked leaf wetness sensor [standard mount]* - checked pyranometer - checked soil moisture sensors (installed vertically) - checked soil temperature senosors (orientation unknown) - checked wind vane (properly aligned) - checked / cleaned atmp/relh sensors (45cm, 1.5m, 3m) - checked / cleaned battery (14.5V) - checked / cleaned solar panel (over 20V) - checked / cleaned tipping-bucket raing gauge (adjusted level) * site does not include a canopy sensor ============================================================================== 12/20/2022: Logger Maintenance: [1020] - checked battery and charging system (good) - replaced modem* * communication issues not resolved 08/12/2022: Station Maintenance: [1005] - routine site maintenance, including: - checked anemometer (bearings good) - checked leaf wetness sensor [standard mount]* - checked pyranometer (good, no adjustments needed) - checked soil sensor cables (good) - checked wind vane (properly aligned) - checked / cleaned tipping-bucket rain gauge - checked / cleaned battery (13.03 V) - checked / cleaned solar panel (20.16 V) - cleaned battery box - cleaned radiation shield on ATMP/RELH sensor - site well-maintained, no weed removal needed * site does not included a canopy sensor 07/12/2022: Station Maintenance: [0935] - routine site maintenance, including: - checked anemometer (good) - checked leaf wetness sensor [standard mount]* - checked pyranometer (good) - checked soil sensors (adjusted install of soil moisture) - checked soil sensor cables (good) - checked wind vane (properly aligned) - checked / cleaned tipping-bucket rain gauge - checked / tested battery (13.23 V) - checked / tested solar panel (20.56 V) - cleaned battery box - site well-maintained, no weed removal needed * site does not included a canopy sensor ============================================================================== 12/03/2021: Logger Maintenance: [1502] - loaded logger program: drf-bbcdS.cr1* - no canopy leaf wetness sensor * supports "maintenance mode" 07/15/2021: Logger / Station Maintenance: [1055] - routine site maintenance 06/09/2021: Station Maintenance [1200] - replaced faulty atmp/relh (hmp155a) sensor 05/27/2021: Station Maintenance [1110] - routine site maintenance - upgraded cell modem - reinstalled 5cm soul temp sensor (soil0) ============================================================================== 06/09/2020: Logger Maintenance: [1100] - replaced logger (CR1000 -> CR1000) - logger program "drf-bbcdS" started 06/07.2020: Logger / Station Maintenance: [1130] - replace wireless modem - added antenna - checked power supply - routine maintenance ============================================================================== 08/16/2019: Logger Maintenance: [1100] - replaced logger (CR1000 -> CR1000) - added PakBus modem - loaded logger program: drf-bbcdS 08/09/2019: Logger Maintenance: [1120] - replaced logger (CR1000 -> CR1000) [failed] - postpone PakBus modem upgrade =============================================================================== 08/07/2018: Station Maintenance: [1010] - annual station / site maintenance 06/26/2018: Logger Maintenance: [0002] - loaded logger program "drf-bbcdS" 06/06/2018: Logger Maintenance: [0031] - loaded logger program "drf-bbcdS" 04/24/2018: Logger Maintenance: [0001] - loaded updated logged program "drf-bbcbS": - program modified to mask-out all canopy leaf wetness (lws1) data. If sensor is ever installed within a representative canopy, logger program will need to be modified. 05/18/2018: Station Maintenance: [1120] - Soybean Inversion Study Upgrade, including: - replace ATMP/RELH sensor @ 1.5m (HMP45C -> HMP155A) - install new ATMP/RELH sensor @ 45cm - install new ATMP/RELH sensor @ 3m - load new logger program "drf-bbcbS" =============================================================================== 07/26/2017: Station Maintenance: [1400] - annual maintenance 06/14/2017: Station Maintenance: [0001] - loaded logger program "drf-bbab" 05/25/2017: Station Maintenance: [1110] - annual maintenance - replaced atmp/relh (HC2S3 -> HMP45C) - atmp/relh now wired to "continuous" power =============================================================================== 10/19/2015: Station Online: [1700] - Station added to Enviroweather/MAWN Web Site 08/31/2015: Data Collection Enabled [1700] - Data Collection and Data Archive for new station begins: First data report: September 01, 2015 (Day=244) 00:05 08/31/2015: Station Maintenance: [1630] - Established telecommunication between station cell-modem and data-collection PC/server on campus. 08/31/2015: Station Setup [1610] - Loaded MAWN Program: DRF-BBBB DRF => Station ID (Deerfield) B => CR1000/MI (Logger/State) B => CS616 (Soil Moisture) B => HC2S3 (Temp/RH) B => LWS-L (Leaf Wetness) - Now able to collect raw weather data. 08/06/2014: Station Installed: [----] - Station installed at station field site ===============================================================================