=============================================================================== Station Notes - Entrican / Lakeview NOTE: Station is located near center-pivot irrigator. The precipitation bucket is covered while irrigating, but care must be taken when using moisture-related variables such as precipitation and soil moisture. ============================================================================== 01/14/2022: Logger Maintenance: [1202] - loaded logger program: ent-bbcbS.cr1* - both standard and canopy leaf wetness sensors * supports "maintenance mode" ============================================================================== 07/26/2021: Station Maintenance: [1310] - routine site maintenance 06/02/2021: Station Maintenance: [1515] - routine site / station maintenance - updated modem ============================================================================== 07/30/2020: Station Maintenance: [1200] - replaced wind sentry (i.e. wind speed / direction) 06/11/2020: Logger / Station Maintenance [1140] - routine site maintenance, including: - replaced leaf wetness sensor (standard mount) - replaced faulty soil temperature sensor (10cm) ============================================================================== 08/09/2019: Logger Maintenance: [1105] - replaced logger (CR1000 -> CR1000) - added PakBus modem - loaded logger program: ent-bbcbS ============================================================================== 09/20/2018: Station Maintenance: [1715] - replaced faulty atmp/relh sensor (1.5m) - checked / tested tipping-bucket rain gauge 07/17/2018: Station Maintenance: [1130] - Soybean Inversion Study Upgrade, including: - logger upgrade (CR10X -> CR1000) - install new ATMP/RELH sensor @ 45cm - install new ATMP/RELH sensor @ 3m - replace leaf wetness sensors (237 -> LWS-L) - load new logger program "ent-bbcbS" 07/02/2018: Station Maintenance: [1315] - general maintenance / cleanup =============================================================================== 11/08/2017: Logger Maintenance: [1701] - load logger program "mawn_adcf" 11/07/2017: Station Maintenance: [1400] - replaced faulty ATMP/RELH sensor (HMP45C -> HMP155A) 08/07/2017: Station Maintenance: [1140] - annual maintenance 05/15/2017: Station Maintenance: [1500] - annual maintenance - cleared precipiation bucket =============================================================================== 08/04/2016: Station Maintenance: [1325] - annual maintenance and weed removal 06/29/2016: Station Maintenance: [1135] - annual maintenance and weed removal =============================================================================== 02/27/2015: Station Maintenance: [0007] - loaded logger program "mawn_abcf" (hourly collection cycle) =============================================================================== 12/23/2014: System Maintenance: [0008] - loaded logger program "mawn_abcw" 11/14/2014: System Maintenance: [1205] - moved data-collection to new LoggerNet server - loaded logger program "mawn_abcf" 05/23/2014: Station Maintenance: [1345] - routine annual maintenance =============================================================================== 05/31/2013: Station Maintenance: [1435] - General station maintenance and system checks, including: - Cleaning of Leaf Wetness Sensor (Standard Mount) - Replacement of Anemometer (i.e. Wind Speed Instrument) =============================================================================== 06/20/2012: Station Maintenance: [1200] - Replaced dead battery - NOTE: Due to faulty battery, data was lost during the following time period: 06/14/2012 (d=166) 1420 - 06/20/2012 (d=172) 1200 - Replaced faulty solar panel/battery cable/connection - Moved station approx. 30-feet to avoid irrigation radius. - NOTE: data prior to 06/20/2012 1200 may contain faulty precipitation data due to irrigation. 06/07/2012: Station Maintenance: [1005] - Replaced Modem 03/14/2012: Station Maintenance: [1145] - Station moved (approx. 500-ft to NW of previous location. - Tipping-bucket rain gauge replaced with a new unit =============================================================================== 05/24/2011: Spring Maintenance: [1235] - Routine Spring Maintenance, including: - Precipitation Bucket Cleaned - Weed-Control Applied - Soil Temp 0 (2") checked and calibrated - Soil Temp 1 (4") replaced =============================================================================== 07/08/2010: Station Maintenance: [1100] - Routine maintence/sensor checks 03/05/2010: Station Maintenance: - Loaded MAWN Program - ABCF (hourly collection cycle) [0006] =============================================================================== 12/19/2009: Station Maintenance: - Loaded MAWN Program - ABCW (3-hour collection cycle) [0004] 06/03/2009: Station Maintenance: [1600] - General station maintenance and system checks, including: - Tipping-bucket rain gauge test (faulty pcpn data that was introduced was removed on 06/08/09) =============================================================================== 05/20/2008: Station Maintenance: - General station maintenance and system checks, including: - Soil Moisture sensors now installed vertically: - MSTR 0: profile of depth = 0 - 12" - MSTR 1: profile of depth = 12 - 24" - Work was done approx: 1600 - 1700 (Day=141) =============================================================================== 10/11/2006: Station Maintenance (jb): - Loaded MAWN Program: MAWN_ABCF (00:05) 08/11/2006: Station Maintenance: (sm, bn): - Communication converted to broadband cell-modem: - Broadband Cell modem installed. - Datalogger Program "mawn_abcs" Loaded and Compiled - Data Collection Configured To Upload Every 30 minutes. - General Station Maintenance and System Checks: - weed removal and application of Round-Up above soil temps - sensor placement checked - anemometer bearings checked - replaced temp/rh sensor (HMP45C) - rain gauge relocated away from center-pivot irrigation - Work was done approx: 11:05 - 11:30 (Day=223) =============================================================================== 07/13/2004: Station Maintenance: (crn, jal) - Tipping Bucket Rain Gauge Calibrated Between 13:00 and 14:00 (Day=195) 04/08/2004: Station Online: - Data Collection and Data Archive for new station begins and now made available via the MAWN website: First data report: Apr 08, 2004 - 00:05 (Day=099) 04/07/2004: Existing Weather Station Upgraded to MAWN Station: Notes: - leaf wetness B (canopy) - still needs to be installed. - Data Logger Program Loaded: MAWN1B Additional Station Needs: ===============================================================================