=============================================================================== Station Notes - Mears (MI) 07/17/2023: Logger Maintenance: [1202] - loaded logger program: mea-bssd.cr6* - standard leaf wetness only [no canopy sensor] * supports "maintenance mode" 06/29/2023: Logger / Station Maintenance: [1230] - communication troubleshooting, including: - replaced modem 06/27/2023: Logger / Station Maintenance: [1230] - communication troubleshooting, including: - power cycle logger and modem (didn't help) 06/21/2023: Station Maintenance: [1125] - routine site maintenance, including: - checked anemometer (good) - checked battery (13.55V) - checked pyranometer (adjusted level) - checked soil sensor cables (good) - checked solar panel (20.07V) - checked tipping-bucket rain gauge (adjusted level) - checked wind vane (properly aligned) - cleaned atmp/relh sensor and radiation shield - cleaned battery terminals - cleaned solar panel - cleaned tipping-bucket rain gauge - replaced leaf wetness sensor (standard)* - weed removal * site does not include a canopy leaf wetness sensor ============================================================================== 08/03/2022: Station Maintenance: [1245] - routine site maintenance, including: - checked anemometer (bearings good) - checked battery (13.27V) - checked battery box (added cover) - checked pyranometer (adjusted level) - checked soil sensor cables (good) - checked solar panel (14.85V) [it was raining] - checked tipping-bucket rain gauge (adjusted level) - checked wind vane (properly aligned) - cleaned atmp/relh sensor and radiation shield - cleaned solar panel - cleaned tipping-bucket rain gauge - tested leaf wetness sensor [standard] (good)* * site does not include a canopy leaf wetness sensor 06/15/2022: Station Maintenance: [1345] - routine site maintenance, including: - checked anemometer (bearings good) - checked soil sensor cables (good) - checked pyranometer (good) - checked wind vane (properly aligned) - checked / cleaned enclosure - checked / cleaned solar panel - checked / cleaned tipping-bucket rain gauge - checked / tested battery (good) - checked / tested leaf wetness [standard] (good)* - cleaned battery box - cleaned hygrovue sensor and radiation shield (atmp/relh) - weed removal * site does not include a canopy leaf wetness sensor =============================================================================== 07/22/2021: Station Maintenance: [1240] - routine site maintenance 05/18/2021: Station Maintenance: [1320] - routine site maintenance, including: - modem update =============================================================================== 06/03/2020: Station Maintenance: [1440] - routine site maintenance =============================================================================== 05/10/2019: Station Online: [1425] - Station added to Enviroweather/MAWN database system 04/29/2019: Data Collection Enabled [1439] - Data Collection and Data Archive for new station begins: First data report: April 30, 2019 (d=120) 00:05 04/29/2019: Logger Setup [1439] - Loaded MAWN Program: mea-bssd mea => Station ID (mears) b => CR1000/MI (Logger/Site) s => SDI-12 [CS650] (Soil Moisture) s => SDI-12 [HygroVue10] (Temp/RH) d => LWS-L (Leaf Wetness) [no canopy] - Now able to collect raw weather data. 04/29/2019: Station Maintenance: [----] - Established telecommunication between station cell-modem and data-collection PC/server on campus. 04/28/2019: Station Setup [----] - station setup/activated at field site ===============================================================================