=============================================================================== Station Notes - Reeman / Fremon-West (MI) 04/27/2023: Station Maintenance: [1120] - routine site maintenance, including: - checked battery (13.67 V) - checked power and sensor cables, clean connnections - checked solar panel (22.6 V) - checked wind vane (properly aligned) - tested leaf-wetness sensor [standard] (fair)* ** - tested pyranometer (good) - tested tipping-bucket rain gauge - replaced anemometer - replaced hygrovue10 (atmp/relh/dwpt) * canopy sensor is not used at this site ** may need to replace standard leaf wetness during next visit =============================================================================== 07/25/2022: Station Maintenance: [1145] - routine site maintenance, including: - checked anemometer (good) - checked battery (13.51 V) - check soil sensor cables (good) - checked solar panel (21.6 V) - checked tipping-bucket rain gauge (level) - checked wind vane (properly aligned) - cleaned atmp/relh sensor and radiation shield - cleaned battery box** - cleaned solar panel - removed leaf wetness sensor [canopy] - replaced hygrovue 10 (atmp/relh/dwpt) - replaced pyranometer - tested leaf wetness sensor [standard] (good)* - tested tipping-bucket rain gauge (good) - weed removal * canopy sensor is not installed in a canopy at this site ** battery cable may need to be replaced during next site visit 06/13/2022: Station Maintenance: [1210] - routine site maintenance, including: - checked anemometer (bearings good) - checked battery (may need new cables next visit) - checked pyranometer (good) - checked soil sensor cables - checked wind vane (proplerly aligned) - checked / tested leaf wetness [standard] (good)* - checked / cleaned solar panel - checked / cleaned tipping-bucket rain gauge (adjusted level) - cleaned atmp/relh sensor and radiation shield - cleaned battery box - weed removal * canopy sensor is attached to tripod leg... not in actual canopy =============================================================================== 07/14/2021: Station Maintenance: [1040] - routine site maintenance 06/04/2021: Station Maintenance: [1110] - routine site maintenance 02/10/2021: Logger Maintenance: [0915] - replaced modem (modem OS update) - reset logger 01/19/2021: Logger Maintenance: [0845] - reset logger/modem (communication issues) 01/26/2021: Logger Maintenance: [0955] - reset logger/modem (communication issues) =============================================================================== 05/29/2020: Station Maintenance: [1250] - routine station maintenance - installed new leaf wetness mount =============================================================================== 05/16/2019: Station Maintenance: [1230] - install soil sensors (i.e. soil temp/moisture) 04/03/2019: Station Online: [----] - Station added to Enviroweather/MAWN database system 03/22/2019: Data Collection Enabled [1450] - Data Collection and Data Archive for new station begins: First data report: March 23, 2019 (d=082) 00:05 03/22/2019: Logger Setup [1445] - Loaded MAWN Program: rfw-bssd rfw => Station ID (conklin) b => CR1000/MI (Logger/Site) s => SDI-12 [CS650] (Soil Moisture) s => SDI-12 [HygroVue10] (Temp/RH) d => LWS-L (Leaf Wetness) [no canopy] - Now able to collect raw weather data. 03/17/2019: Station Maintenance: [----] - Established telecommunication between station cell-modem and data-collection PC/server on campus. 03/17/2019: Station Setup [----] - station setup/activated at field site ===============================================================================