============================================================================== Station Notes - South Haven 01/24/2024: Logger Maintenance: [0005] - replaced logger (CR1000 -> CR6)* - logger program: shv-bssd.cr6** * installed: 11/14/2023 * enabled: 01/24/2024 ** includes atmp/relh sensor upgrade (dwpt now observed) ** includes soil sensor upgrade ** does not report canopy leaf wetness (no canopy sensor) ============================================================================== 07/23/2023: Station Maintenance: [1100] - routine site maintenance, including: - checked anemometer (good) - checked atmp/relh sensor (good) - checked battery (13.4 V) - checked pyranometer (adjusted level) - checked soil sensors (good) - checked solar panel (19.36 V) - checked tipping-bucket rain gauge (adjusted level) - checked wind vane (properly aligned) - cleaned atmp/relh sensor and radiation shield - tested leaf wetness sensor [standard] (good)* - weed removal * canopy leaf wetness faulty since 05/29/2019 05/24/2023: Station Maintenance: [1215] - routine site maintenance, including: - checked anemometer (bearings sound good) - checked atmp/relh sensor (good) - checked battery (13.61V) - checked pyranometer (adjusted level) - checked soil sensor cables (good) - checked solar panel (19.02V) - checked tipping-bucket rain guage (adjusted level) - cleaned battery box - cleaned solar panel - tested leaf wetness sensor [standard] (good)* * site does not include a canopy sensor 03/30/2023: Station / Logger Maintenance [1515] - site maintenance, including: - reinstalled soil moisture sensors - sensor 0: vertical 00-30cm - sensor 1: vertical 30-60cm - reinstalled soil temperature sensors - sensor 0: horizontal 02" - sensor 1: horizontal 04" - checked anemometer (good) - checked tipping-bucket rain gauge (adjusted level) - checked wind vane (properly aligned) - checked / tested leaf wetness sensor (standard... good) - checked / tested leaf wetness sensor (canopy... NAN) ============================================================================== 07/13/2022: Station Maintenance [1135] - routine site maintenance, including: - checked battery (13.6 V) - checked pyranometer (adjusted level) - checked soil sensor cables (good) - checked solar panel (19.0 V) - checked wind vane (properly aligned) - checked / cleaned tipping-bucket rain gauge - checked / tested leaf wetness sensor (standard... good) - cleaned atmp/relh radiation shield - cleaned solar panel - replaced anemometer (bearings sounded bad) 06/01/2022: Station / Logger Maintenence [1040] - routine site maintenance, including: - checked anemometer (replace bearings next visit) - checked battery (good) - checked pyranometer (good, level) - checked soil sensor cables (good) - checked wind vane (good condition, properly aligned) - checked / cleanded solar panels - checked / cleaned tipping-bucket rain gauge - checked / tested leaf wetness sensor (canopy... good) - checked / tested leaf wetness sensor (standard... good) - cleaned battery box - repaired HMP155 (atmp/relh) - weed removal ============================================================================== 07/06/2021: Station Maintenance: [1405] - routine site maintenance 05/18/2021: Station / Logger Maintenance: [1220] - routing site maintenance, including: - modem update =============================================================================== 08/04/2020: Station / Logger Maintenance: [1245] - replaced battery - replaced HMP155 (atmp/relh) 05/22/2020: Station Maintenance: [1540] - routine site maintenance =============================================================================== 06/19/2019: Logger Maintenance: [1005] - replaced logger (CR1000 -> CR1000) - added PakBus modem - loaded logger program: shv-bbca =============================================================================== 11/11/2018: Logger Maintenance: [1500] - replaced faulty logger battery 09/07/2018: Station Maintenance: [1200] - replaced faulty atmp/relh sensor - loaded logger program (shv-bbca) 07/30/2018: Station Maintenance: [1250] - general maintenance / weed removal 06/04/2018: Station Maintenance: [1250] - general maintenance / weed removal =============================================================================== 11/07/2017: Station Maintenance: [0900] - replaced logger battery (35 amp battery installed) 09/19/2017: Station Maintenance: [0005] - loaded logger program "shv-bbaa" 07/17/2017: Station Maintenance: [1135] - annual maintenance, including: - rewire of atmp/relh (HMP45C) to "continuous" power 05/08/2017: Station Maintenance: [1500] - annual maintenance =============================================================================== 05/31/2016: Station Maintenance: [1500] - annual maintenance and weed removal 02/26/2016: Station Maintenance: [1300] - replaced faulty battery - installed additional 10W panel 01/18/2016: Station Maintenance: [1500] - replaced faulty battery =============================================================================== 12/23/2015: Station Maintenance: [1500] - replaced faulty CR10/CR10X logger with CR1000 logger 02/26/2015: Station Maintenance: [0008] - loaded logger program "mawn_abcf" (hourly collection cycle) =============================================================================== 12/18/2014: System Maintenance: [0002] - loaded logger program "mawn_abcw" 12/10/2014: Station Maintenance: [????] - faulty battery replaced 08/26/2014: Station Maintenance: [1415] - replaced 2" Soil Temperature (soil0) sensor 03/06/2014: Station Maintenance: [1508] - Moved data-collection to new LoggerNet server - Loaded logger program: ABCF (hourly cycle) =============================================================================== 12/17/2013: Station Maintenance: [1200] - Replaced logger battery 12/14/2013: Station Maintenance: [0004] - Loaded Logger Program "ABCW" (3-hour collection cycle) 05/08/2013: Station Maintenance: [1330] - Leaf Wetness Sensors Calibrated 05/07/2013: Station Maintenance: [1300] - Replaced Leaf Wetness 0 (Standard Mount). - Due to faulty sensor, Leaf Wetness 0 Data removed for the following time period: 04/21/2013 (d=111) 08:00 - 05/07/2013 (d=127) 13:00 02/16/2013: Station Maintenance: [0007] - Loaded Logger Program - ABCF (hourly collection cycle) =============================================================================== 12/14/2012: Station Maintenance: [1200] - Battery Replaced. Recent battery issues have led to occasional loss of data. 12/12/2012: Station Maintenance: [1133] - Loaded Logger Program - ABCW (3-hour collection cycle) - Waiting for battery replacement. =============================================================================== 05/16/2011: Station Maintenance: [0002] - Loaded MAWN Program - ABCS (30-minute collection cycle) =============================================================================== 10/14/2011: Station Maintenance: [0004] - Loaded MAWN Program - ABCF (60-minute collection cycle) 05/02/2011: Station Maintenance: [0001] - Loaded MAWN Program - ABCS (30-minute collection cycle) 03/13/2011: Station Maintenance: [0005] - Loaded MAWN Program - ABCF (hourly collection cycle) =============================================================================== 12/08/2010: Station Maintenance: [0004] - Loaded MAWN Program - ABCW (3-hour collection cycle) 03/08/2010: Station Maintenance: [1515] - Old CR10 logger was replaced with CR10X. - MAWN Program ABCF (hourly schedule) loaded. =============================================================================== 06/23/2009: Data Quality: [1700] - Faulty air temp, humidity, and soil temp (2" depth) data that was introduced due to failing sensors during the following time period was removed from the MAWN data archive: 09/12/09 (d=255) 22:00 - 09/18/09 (d=261) 10:50 09/18/2009: Station Maintenance: [1100] - Faulty Air Temp/Relative Humidity and Soil Temp 0 (2") sensors were replaced. 06/15/2009: Data Quality: [1400] - Wind vane was replaced on 06/09/09. As a result, all of previous wind direction data that appeared to be incorrect was removed from the MAWN data archive - wind direction data that was reported during the following time period was removed: 04/06/06 (d=096) 00:05 - 06/09/09 (d=160) 12:00 06/09/2009: Station Maintenance: [1200] - General station maintenance and system checks, including: - Tipping-bucket rain gauge test (faulty pcpn data that was introduced was removed on 06/11/09). - Wind vane replaced. 03/04/2009: Station Maintenance: - Loaded MAWN Program - ABCF (hourly power cycle) [0003] =============================================================================== 12/07/2008: Station Maintenance: - Loaded MAWN Program - ABCW (3-hour power cycle) [0107] 03/31/2008: Telecommunication Trouble Corrected: (sm) - Wireless broadband modem was replaced (11:30). As of 12:00pm, station is back online =============================================================================== 10/24/2007: Data Correction (jb): - Unknown problem led to several faulty data entries in early September. Problem seems to have been isolated to the 09/02/07 - 09/10/07 time period. The following five-minute (and associated hourly and daily) data entries have been removed from both the archived raw data and the MAWN database: 09/02/2007 (d=245): 2220 09/03/2007 (d=246): 2015-2020, 2223-2230 09/04/2007 (d=247): 0605, 0910, 0925, 1245 09/08/2007 (d=251): 0410-0415, 0640-0705 09/09/2007 (d=252): 1025-1030, 1125-1130 09/10/2007 (d=253): 0305-0405, 1050-1315 04/18/2007: Telecommunication Trouble Corrected: (sm) - Wireless broadband modem was repaired and replaced (09:30) 04/10/2007: Telecommunication Troubles: - Wireless broadband modem has failed at the South Haven MAWN station. The modem has been pulled and now waiting for repair/replacement. Planning on repairs to be made later next week. =============================================================================== 10/18/2006: Station Maintenance: (bn): - Replaced Power Supply (Battery) (14:15) 09/22/2006: Station Maintenance (jb): - Loaded MAWN Program: MAWN_ABCF (00:05) 09/07/2006: Station Maintenance: (jb): - Loaded MAWN Program: MAWN_ABCS (16:05) 04/18/2006: Station Online: - Station added to MAWN web site. 04/06/2006: Data Collection Enabled: - Data Collection and Data Archive for new station begins: First data report: Apr 06, 2006 - 00:05 (Day=96) 04/05/2006: Station Maintenance: - Established telecommunication between station cell-modem and data collection PC/server on campus. Now able to collect raw weather data. 04/05/2006: New Station Installed: Notes: - leaf wetness B (canopy) - still needs to be installed. - Data Logger Program Loaded: MAWN_BBCS Additional Station Needs: ==============================================================================