Enviro-weather, formerly Michigan Automated Weather Network

conklin — Maintenance Reports

Download maintenance log

: Station Maintenance [1250]

- routine site maintenance, including:

- checked anemometer (replaced bearings)

- checked pyranometer (good... no adjustments needed)

- checked soil sensor cables (good)

- checked / cleaned solar panel

- checked / tested battery

- checked / tested leaf wetness [canopy] (good)+

- checked / tested leaf wetness [standard] (good)

- cleaned / tested tipping-bucket rain gauge

- weed removal not needed (site already well maintained)

* canopy sensor is attached to tripod leg... not in actual canopy

: Station Maintenance [1055]

- routine site maintenance

: Station Maintenance [1245]

- routine site maintenance, including:

- modem update

: Station Maintenance [1450]

- routine station maintenance

- installed new leaf wetness mount

: Logger Maintenance [0004]

- load logger program "cnk-bssb"*

* supports canopy leaf wetness

: Station Maintenance [1545]

- install soil sensors (i.e. soil temp/moisture)

- install canopy leaf wetness

: Station Online [0930]

- Station added to Enviroweather/MAWN database system

: Data Collection Enabled [1440]

- Data Collection and Data Archive for new station begins:

First data report: March 23, 2019 (d=082) 00:05

: Logger Setup [1435]

- Loaded MAWN Program: cnk-bssd

cnk => Station ID (conklin)

b => CR1000/MI (Logger/Site)

s => SDI-12 [CS650] (Soil Moisture)

s => SDI-12 [HygroVue10] (Temp/RH)

d => LWS-L (Leaf Wetness) [no canopy]

- Now able to collect raw weather data.

: Station Maintenance: [----]

- Established telecommunication between station cell-modem

and data-collection PC/server on campus.

: Station Setup [----]

- station setup/activated at field site