dowagiac — Maintenance Reports
Download maintenance log
: Station Maintenance [1220]
- routine site maintenance, including:
- checked anemometer (good)
- checked atmp/relh sensor (good)
- checked soil sensor cables (good)
- checked tipping-bucket rain gauge (adjusted level)
- cleaned battery box
- cleaned solar panel
- replaced leaf wetness sensor [standard]
* canopy sensor located near an apple tree
: Station Maintenance [1055]
- site maintenance, including:
- replaced atmp/relh sensor (hmp155)
: Station Maintenance [1320]
- routine site maintenance, including:
- checked anemometer (ok, but bearings are old)
- checked battery (13.04V)
- checked enclosure (replaced desipacks)
- checked pyranometer (good)
- checked soil sensor cables (good)
- checked solar panel (20.84V)
- checked tipping-bucket rain gauge (good)
- checked wind vane (properly aligned)
- cleaned atmp/relh sensor and radiation shield*
- cleaned battery box
- tested leaf wetness sensor [canopy] (good)
- tested leaf wetness sensor [standard] (good)
- weed removal
* replacement needed at next site visit
: Station / Logger Maintenence [1325]
- routine site maintenance, including:
- adjusted (leveled) pyranometer
- adjusted soil moisture sensors (installed vetically)
- checked anemometer (fair)
- checked battery (good)
- checked tipping-bucket rain gauge
- checked wind vane (good)
- cleaned solar panel
: Station Maintenance [1135]
- routine site maintenance
: Station Maintenance [1445]
- replaced atmp/relh sensor
: Logger Maintenance [1700]
- replaced cell modem (modem OS upgrade)
: Station Maintenance [1330]
- replaced leaf wetness sensor (canopy)
- data cleanup performed on leaf wetness (standard / canopy)
: Logger / Station Maintenance [1500]
- repaired communication issue (down since 11/12/2020)
- replaced faulty soil moisture sensor (mstr1)
: Logger Maintenance [1130]
- power system upgrade
: Station Maintenance [1140]
- routine site maintenance
- replaced atmp/relh sensor
: Logger Maintenance [1005]
- replaced logger (CR1000 -> CR1000)
- added PakBus modem
- loaded logger program: dow-bbab
: Station Maintenance [1200]
- removed obstruction from tipping-bukce tain gauge
: Station Maintenance [1320]
- site maintenance
: Station Maintenance [1515]
- annual maintenance, including:
- leaf wetness cleaning
- precipitation test
- site cleanup / weed removal
: Station Maintenance [1445]
- general maintenance
: Station Maintenance [0002]
- loaded logger program: dow-bbab
: Station Maintenance [1040]
- annual maintenance, including:
- replacement of canopy leaf wetness
- replacement of atmp/relh sensor (HC2S3 -> HMP45C)
- atmp/relh now wired to "continuous" power
: Station Maintenance [1300]
- annual maintenance and weed removal
: Station Maintenance [1230]
- annual maintenance and weed removal
: Station Maintenance [1230]
- corrected mounting of tipping-bucket rain gauge
: Station Maintenance [1300]
- replaced LEAF WETNESS 1 (canopy sensor)
- leveled precipitation bucket
: Station Online [1420]
- Station added to Enviroweather/MAWN Web Site
: Data Collection Enabled [1600]
- Data Collection and Data Archive for new station begins:
First data report: April 17, 2014 (Day=107) 00:05
: Station Installed [1400]
- Station installed at station field site
: Station Maintenance [1545]
- Established telecommunication between station cell-modem
and data-collection PC/server on campus.
: Station Setup [1525]
- Loaded MAWN Program: BBBB-DOW
B => CR1000/MI (Logger/State)
B => CS616 (Soil Moisture)
B => HC2S3 (Temp/RH)
B => LWS-L (Leaf Wetness)
DOW => Station ID (Dowagiac)
- Now able to collect raw weather data.