Enviro-weather, formerly Michigan Automated Weather Network

fennville — Maintenance Reports

Download maintenance log

: Station Maintenance [1125]

- routine station maintenance, including:

- checked anemometer (good)

- checked atmp/relh sensor (good)

- checked battery (13.51V)

- checked pyranometer (good)

- checked soil sensor cables (good)

- checked solar panel (21.25V)

- checked tipping-bucket rain gauge (adjusted level)

- cleaned battery box

- cleaned solar panel

- tested leaf wetness sensor [canopy] (good)

- tested leaf wetness sensor [standard] (good)

: Station Maintenance [0945]

- routine station maintenance, including:

- checked anemometer (bearings good)

- checked battery (13.63V)

- checked soil sensor cables (good)

- checked solar panel (20.56V)

- checked tipping-bucket rain gauge (cleaned, adjusted level)

- checked wind vane (properly aligned)

- cleaned solar panel

- replaced pyranometer

- tested leaf wetness sensor [canopy] (good)

- tested leaf wetness sensor [standard] (good)

: Station Maintenance [1040]

- replaced atmp/relh/dwpt sensor

- replaced pyranometer (solar radiation) sensor

- replaced leaf wetness sensors (standard, canopy)

: Station Maintenance [1030]

- routine site maintenance

: Station Maintenance [1300]

- routine site maintenance, including...

...replacement of soil temp/moisture (5cm) sensor

: Station Maintenance [1130]

- routine site maintenance

: Logger Maintenance [1400]

- replaced modem (modem OS update)

: Logger Maintenance [1345]

- reset logger / modem (communication issues)

: Logger Maintenance [1500]

- reset modem (communication issues)

: Station Maintenence [1430]

- routine site maintenance, including...

...remount of leaf wetness sensors (standad, canopy)

: Logger Maintenance [1630]

- replaced logger (CR1000 -> CR6)

- added PakBus modem

- loaded logger program: fev-bssb

: Station Maintenance [1155]

- general maintenance / weed removal

: Station Maintenance [1200]

- annual station / site maintenance

: Station Maintenance [1445]

- annual maintenance

: Station Maintenance [1050]

- annual maintenance

: Station Maintenance [0007]

- loaded logger program "fev-bbab"

: Station Maintenance [1245]

- replaced air temp/relh sensor (HC2S3 -> HMP45C)

- sensor now connected to "continuous" power

: Station Maintenance [1430]

- annual maintenance and weed removal

: Station Maintenance [1445]

- annual maintenance and weed removal

- installed 10w solar panel

: Station Modernization [1300]

- Station upgraded with new logger and serveral new sensors.

- loaded logger program "fev-bbbb"

- Due to upgrade, station was offline for the following:

05/28/2015 (d=148) 1305 - 05/28/2015 (d=148) 1500

- the "live" data updates were able to resume at:

05/29/2015 (d=149) 1055

: Station Maintenance [0003]

- loaded logger program "mawn_abcf" (hourly collection cycle)

: System Maintenance [0007]

- loaded logger program "mawn_abcw"

: Station Maintenance [1030]

- faulty battery replaced

: Station Maintenance [1400]

- routine maintenance

: Station Maintenance [1645]

- Routine maintenance

- cleaned temp/rh sensor

: Station Maintenance [1504]

- Moved data-collection to new LoggerNet server

- Loaded logger program: ABCF (hourly cycle)

: Station Maintenance [1500]

- Replaced Logger battery

: Station Maintenance [1203]

- Loaded Logger Program "ABCW" (3-hour collection cycle)

: Station Maintenance [1500]

- Replaced both leaf wetness sensors

: Station Maintenance [0002]

- Loaded Logger Program - ABCF (hourly collection cycle)

: Station Maintenance [1555]

- Added "hourly battery voltage" to hourly database table

: Station Maintenance [1210]

- Loaded MAWN Program - ABCW (03-hour collection cycle)

: Station Maintenance [1155]

- Station converted to Wireless Broadband communications

: Station Maintenance [1500]

- Communications cable was accidentally cut during local

trenching work. Field staff was able to splice cable

back together before any data was lost.

: Station Maintenance [1400]

- General station maintenance and system checks, including:

- Tipping-bucket rain gauge test (faulty pcpn data

that was introduced was removed on 06/11/09)

- Anemometer was replaced (noisy bearings)

: Station Maintenance (sm)

- It appears that Leaf Wetness 0 (Standard Mount) has been

a bit unreliable as several instances of "missing" have

recently appreared in the 5-minute leaf wetness data.

To correct this problem, the stanard leaf-wetness

sensor was replaced this morning (10:15am)

: Data Quality Control (jb)

- Faulty precipitation data that was introduced on

July 31 (day=212) was removed from archived raw

data file. Entries in MAWN database were also

corrected.

: Station Maintenance (sm)

- Sensor Calibration/Testing:

- Manual test of precipitation bucket.

- Testing led to introduction of fauly PCPN data

at 825 (five-minute), 900 (hourly) and 2400 (daily).

: Station Maintenance (bn)

- Sensor replacement:

- Soil Moisture A and Soil Moisture B both replaced (CS616)

- Datalogger progam "mawn1c" loaded and compiled.

- General station maintenance and system checks.

- Work was done approx: 14:00 - 15:00 (Day=192)

: Station Maintenance (sm, bn)

- General station maintenance and system checks.

- Work was done approx: 13:40 - 14:20 (Day=129)

: Station Maintenance (mh)

- Recent data loss due to existing battery being sensitive

to cold weather which would cause the battery to periodically

fail.

- New battery was installed this morning.

: Station Maintenance (mh)

- Funnel to the tipping bucket on the rain gauge was

plugged. Debris was removed and obstruction was

cleared this afternoon (09/30/05 - Day=273)

: Station Maintenance (sm)

- General Station Maintenance and System Checks:

- weed removal and application of Round-Up above soil temps

- cleaned/checked all sensors

- cleaned/serviced precipitation bucket

- approximate time of service: 1:15pm

: Station Maintenance (sm)

- Datalogger Failure on Day=67 (03/08/2005). Datalogger

Program MAWN1B reloaded at 14:30 on Day=73 (03/14/2005).

Data collection once again operational.

- Due to Datalogger outage, data for the following time

period is not available:

Day=67 (03/08/2005): 04:15 - Day=73 (03/14/2005): 14:25

: Station Maintenance (jal)

- Replaced Temperature/Relative Humidity Sensor (HMP45C).

- General Station Maintenance and System Checks:

- weed removal and application of Round-Up above soil temps

- Work was done approx: 14:05 - 14:20 (Day=238)

: Station Maintenance (sm, jal)

- Replaced Tipping Bucket Rain Gauge.

: Station Update (crn,sm)

- Leaf Wetness B (canopy) sensor installed. The sensor

was placed in a shrub planted near the foot of the NE

leg of the station.

: Daylight Savings Time Adjustment.

- Daylight Savings Time Started on Day=97, Time=200.

- Time of Obs were modified by one hour (forward)

from Day=97, Time=200 through Day=98, Time=1225.

: Field Work: (Jeff Andresen, Jim Brown)

- Installed Pressure sensor. However, no changed made

to datalogger program so pressure is currently not

being recorded.

- Relocated Leaf Wetness A:

Bracket mounted 40-inches from center of tripod,

39-inches (~1m) high. Mounted on NE leg, sensor

facing north.

: Daylight Savings Time Adjustment.

- Daylight Savings Time Ended on Day=301, Time=200.

- Time of Obs were modified by one hour (subtracted)

from Day=301, Time=200 through Day=303, Time=900.

: Field Maintanence

- Reburied Soil Temperatures - installed in SW

quadrant of station:

Soil A: 2-inches under sod, W of S leg, N of Soil B

Soil B: 4-inches under sod, W of S leg, S of Soil A

- Buried Soil Temperature Probe (Horizontal Placement)

is SE quadrant of station:

Soil Moisture A: 10" depth, E of S leg, facing south

- Moved Pyranometer Stand to face SW (originally was

oriented to the SE).

- Needs:

Leaf Wetness A needs to be moved to standard mount

on NE leg.

Additional LeaF Wetness (Sensor B)

Additional Soil Moisture (Sensor B)

NOTE: Current Soil Moisture needs to be switched

in the datalogger. Sensor A should be buried

at 4" and Sensor B should be placed at 10".

: Daylight Savings Time Adjustment.

- Daylight Savings Time Started on Day=91, Time=200.

- Time of Obs were modified by one hour (added) from

Day=91, Time=200 through Day=91, Time=1500.

Observation Times, including times of max/mins

were modified.

: Daylight Savings Time Adjustment.

- Daylight Savings Time Ended on Day=303, Time=200.

- Time of Obs were modified by one hour (subtracted)

from Day=303, Time=200 through Day=303, Time=1500.

Only Observation Times were modified, not times of

Maxs and Mins. Users will need to take that into

consideration when using this data.

: Fennville station added to MAWN database

: Station Update

- Uploaded Program: mawn1b (10:26am)

- Test Tipping Bucket (10:50am)

- Moved Soil Temps from SE corner to SW:

Soil A: 2-inches under sod, W of S leg, N of Soil B

Soil B: 4-inches under sod, W of S leg, S of Soil A

- Notes:

Soil Moisture A = E of S leg is bent.

Need two new soil moisture probes, additional leaf

wetness sensor, and need to move Pyranometer to face

to the SW.

Leaf Wetness A is mounted at the end of NW leg at

a height of 20.5". May need to moved to standard

install off of NE leg (40" from center of tripod,

39" high).