freeland — Maintenance Reports

Download maintenance log

: Station Maintenance [1110]

- routine site maintenance, including:

- checked anemometer (good)

- checked battery (13.68 V)

- checked enclosure (re-sealed wire access entry)

- checked pyranometer (adjusted level)

- checked soil sensors (good)

- checked solar panel (20.4 V)

- checked tipping-bucket rain gauge (adjusted level)

- checked leaf wetness [standard] sensor (good)*

- checked wind vane (properly aligned)

- cleaned atmp/relh sensor and radiation shield

- cleaned battery terminals

- cleaned solar panel

- cleaned tipping-bucket rain gauge

- weed removal / trim grass

* site does not include a canopy sensor

: Logger / Station Maintenance [1105]

- loaded logger program: frl-bbad.cr1* (237 -> LWS-L)**

* supports "maintenance mode"

** sensor replaced: 06/05/2020 (no canopy)

- cleaned-up previously collected data

: Station Maintenance [1045]

- site maintenance, including:

- checked atmp/relh sensor (good)

- checked battery (12.55V)

- checked leaf wetness sensor [standard] (incomplete)*

- checked solar panel (16.1V)

- cleaned solar panel

- replaced charge controller and 12V power switch

- replaced soil moisture sensors (mstr0, mstr1)

- replaced soil temperature sensors (soil0, soil1)

- replaced tipping-bucket rain gauge

- replaced wind sentry (anemometer / wind vane)

* unable to test... logger program upgraded needed

* site does not include a canopy sensor

: Station Maintenance [1350]

- routine site maintenance, including:

- replaced soil temperature sensor [soil1 @ 4"]*

* reinstalled soil0 @ 2"

: Station Maintenance [1315]

- routine site maintenance, including:

- modem update

: Station Maintenance [1115]

- routine site maintenance, including:

- leaf wetness sensor upgrade [stadard] (237 -> LWS)*

* standard sensor only... site does not include canopy sensor

: Station Maintenance [1215]

- replaced wind vane

: Logger / Station Maintenance [1255]

- replaced logger (CR10X -> CR1000)

- added PakBus modem

- loaded logger program: frl-bbac

: Station Maintenance [1150]

- correct communication issues

: Station Maintenance [1130]

- cleared obstruction from tipping-bucket rain gauge

: Station Maintenance [1615]

- replaced faulty anemometer (wind speed)

: Station/Logger Maintenance [1515]

- replaced logger battery

- replace atmp/relh sensor (HMP45C) [faulty relh]

: Logger Maintenance [1045]

- troubleshoot logger / battery issues

: Logger Maintenance [1310]

- replaced logger battery

: Station Maintenance [1115]

- precipitation gauge maintenance (unplug)

: Station Maintenance [0009]

- loaded logger program "mawn_abcf" (hourly collection cycle)

: System Maintenance [0002]

- loaded logger program "mawn_abcw"

: Station Maintenance [1140]

- faulty battery replaced

: System Maintenance [1208]

- moved data-collection to new LoggerNet server

- loaded logger program "mawn_abcf"

: Station Maintenance [1335]

- routine annual maintenance, including:

- cleaned air temp / rh sensor

- anemometer bearings checked

- weed removal

: Station Maintenance [1415]

- Repaced Modem

- Cleaned Leaf Wetness Sensors

: Station Maintenance [1150]

- Replaced Modem

- Provide Updated GPS Info:

LAT: 43.5631

LON: -84.0233

: Station Maintenance: [????]

- Routine maintence, including:

- weed/grass removal

: Station Maintenance [1400]

- General station maintenance and system checks, including:

- Tipping-bucket rain gauge test (faulty pcpn data

that was introduced was removed on 06/08/09)

: Station Maintenance [1115]

- Telecommunication trouble with the Freeland MAWN

station was corrected - broadband modem was replaced.

- Due to the recent trouble, nearly two weeks of data

was lost. Data for the following time period is

not available:

01/26/09 (d=026) 0205 - 02/09/09 (d=040) 1715

: Station Maintenance

- General station maintenance and system checks, including:

- Soil Moisture sensors now installed vertically:

- MSTR 0: profile of depth = 0 - 12"

- MSTR 1: profile of depth = 12 - 24"

- Leaf Wetness A (standard) was replaced

- Work was done approx: 1100 - 1145 (Day=150)

: Station Maintenance (jb)

- Loaded MAWN Program: MAWN_ABCF (1-hr power cycle) [15:07]

: Station Maintenance (bn)

- Station moved to new location at site:

- Missing data between 11:45 - 15:10 (Day=127) because

of the station move.

- Communication converted to broadband cell-modem:

- Broadband cell-ip modem installed

- Datalogger progam "mawn_abcs" loaded and compiled.

- Battery voltage now reported every hour.

- Data collection configured to upload every 30 minutes.

- General station maintenance and system checks.

- replaced bearings in anemometer.

- Work was done approx: 11:45 - 15:30 (Day=127)

: Station Added to MAWN Web Site.

: Data Collection and Data Archive for new station begins

First report: August 21, 2004 - 00:05 (Day=234))

: Station Maintenance (jal)

: Station Maintenance (crn)

- Troubleshoot communications/datalogger troubles.

Appears to need new power supply (regulator) as

well as a new wiring panel.

- Rewired Temperature/Relative Humidity Sensor (HMP45C).

The previous connection seemed to draw too much power.

: Station Maintenance: (crn, jal)

- Schedule to Power Modem Corrected

: New Station Installed: (crn, jal)

Notes:

- datalogger program: MAWN1E (cell phone, CS616, HMP45C)

Additional Station Needs: