Enviro-weather, formerly Michigan Automated Weather Network

haslett — Maintenance Reports

Download maintenance log

: Station Maintenance [1035]

- routine site maintenance, including:

- checked anemometer (good)

- checked atmp/relh sensor

- checked battery (12.94 V)

- checked leaf wetness [standard] sensor (good)*

- checked pyranometer (good)

- checked soil sensors (good)

- checked solar panel (20.75 V)

- checked tipping-bucket rain gauge (good)

- checked wind vane (properly aligned)

- cleaned atmp/relh sensor and radiation shield

- cleaned battery box (remove mice and nest)

- cleaned battery terminals

- cleaned solar panel

- weed removal

* site does not include a canopy sensor

: Station Maintenance [1340]

- routine site maintenance, including:

- checked anemometer (bearings good)

- checked battery (13.32 V)

- checked soil sensors (good)

- checked solar panel (21.25 V)

- checked tipping-bucket rain gauge

* site does not include a canopy sensor

: Station Maintenence [1450]

- routine site maintenance, including:

- checked anemometer (bearings good)

- checked battery (13.17 V)

- checked soil sensor cables (tightened connections)

- checked wind vane (properly aligned)

: Station Maintenance [1050]

- routine site maintenance, including:

- checked battery (13.22 V)

- checked pyranometer (good)

- checked soil sensor cables (good)

- checked solar panel (20.75 V)

- checked tipping-bucket rain gauge (good)

- checked wind vane (properly aligned)

- cleaned battery box

- cleaned atmp/relh sensor and radiation shield

- tested leaf wetness sensor [standard} (good)*

- weed removal

* site does not include a canopy sensor

: Station Maintenance [1010]

- routine site maintenance, including:

- checked anemometer (good)

- checked battery (13.1 V)

- checked pyranometer (good)

- checked soil sensor cables (good)

- checked solar panel (21.06 V)

- checked wind vane (properly aligned)

- cleaned atmp/relh sensor and radiation shield

- cleaned battery box

- tested leaf wetness sensor [standard] (good)*

- weed removal

* site does not include a canopy sensor

: Station Maintenance [1100]

- routine site maintenance

: Station Maintenance [1620]

- repaired tipping bucket rain gauge (cleared obstruction)

: Logger / Station Maintenance [0930]

- routine site maintenance

: Station Maintenance [1015]

- routine site maintenance

: Station Maintenance [0945]

- replaced faulty pyranometer (solar radiation)

: Station Maintenance [1100]

- repaired HMP155A sensor (atmp/relh/dwpt)

: Station Maintenance [1000]

- clean / test rain gauge

: Logger Maintenance [0005]

- activated new CR6 logger

- loaded logger program: has-bssd [no canopy]

--/--2019: Station Maintenance: [----]

- installed new CR6 station to replace CR1000

- added PakBus modem

: Station Maintenance [0915]

- replaced faulty lws1 (canopy leaf wetness) sensor

: Station Maintenance [1630]

- routine station / site maintenance

: Station Maintenance [1130]

- annual station / site maintenance

: Station Maintenance [1115]

- annual maintenance

: Station Maintenance [1015]

- annual maintenance

: Station Maintenance [0001]

- loaded logger program "has-bbab"

: Station Maintenance [1350]

- annual maintenance

- replaced atmp/relh (HC2S3 -> HMP45C)

- atmp/relh now wired to "continuous" power

: Station Maintenance [1000]

- replaced 2" Soil Temp (soil0)

- cleared obstruction from precipitation bucket

: Station Maintenance [1230]

- cleared snow/ice from solar panel

: Station Maintenance [1130]

- annual maintenance and weed removal

- clean tipping bucket rain gauge

: Station Maintenance [1530]

- replaced faulty 2" soil temperature sensor (SOIL0)

: Station Online [1330]

- Station added to Enviroweather/MAWN Web Site

: Station Maintenance [1530]

- Replaced LI200S pyranometer (solar radiation) with LI200X

- Replaced faulty HC2S3 (air temp/rh).

- Replaced faulty RH and Solar Radiation data with esitmates

for the following time period:

04/02/2015 (d=092) 0005 - 04/14/2015 (d=104) 1600

: Station Maintenance [0003]

- Decagon sensors are installed in field, not 237 sensors

Loaded logger program "bbbb-has" to allow for proper

collection of leaf wetness data.

: Data Collection Enabled [1250]

- Data Collection and Data Archive for new station begins:

First data report: April 02, 2015 (Day=092) 00:05

: Station Installed [1400]

- Station installed at station field site

: Station Maintenance [1705]

- Established telecommunication between station cell-modem

and data-collection PC/server on campus.

: Station Logger Setup [1638]

- Loaded MAWN Program: BBBA-HAS

B => CR1000/MI (Logger/State)

B => CS616 (Soil Moisture)

B => HC2S3 (Temp/RH)

A => 237 (Leaf Wetness)

HAS => Station ID (Haslett)

- Now able to collect raw weather data.