: Logger / Station Maintenance [1605]
- loaded logger program: lin-bbad.cr1* (237 -> LWS-L)**
* supports "maintenance mode"
** sensor replaced: 07/23/2020 (no canopy)
- cleaned-up previously collected data

- loaded logger program: lin-bbad.cr1* (237 -> LWS-L)**
* supports "maintenance mode"
** sensor replaced: 07/23/2020 (no canopy)
- cleaned-up previously collected data
- routine site maintenance, including:
- checked anemomter (good)
- checked battery (13.28 V)
- checked leaf wetness [standard] sensor (new program needed)*
- checked pyranometer (good)
- checked solar panel (19.2 V)
- checked tipping-bucket rain gauge (adjusted level)
- checked wind vane (properly aligned)
- cleaned atmp/relh sensor and radiation shield
- weed removal
* site does not include canopy sensor
- routine site maintenance, including:
- checked anemometer (good)
- checked battery (13.45 V)
- checked leaf wetness [standard] sensor (new program needed)*
- checked pyranometer (adjusted level)
- checked soil sensors (good)
- checked solar panel (16.62 V)
- checked tipping-bucket rain gauge
- checked wind vane (properly aligned)
- cleaned atmp/relh sensor and radiation shield
- cleaned battery terminals
- cleaned solar panel
- cleaned tipping-bucket rain gauge
- weed removal
* site does not include a canopy sensor
- routine site maintenance, including:
- checked anemometer (good)
- checked leaf wetness [standard] sensor (new program needed)*
- checked pyranometer (adjusted level)
- checked soil sensor cables (good)
- checked tipping-bucket rain gauge (adjusted level)
- checked wind vane (properly aligned)
- cleaned atmp/relh sensor and radiation shield
- cleaned solar panel
- cleaned tipping-bucket rain gauge
* site does not include a canopy sensor
- routine site maintenance, including:
- checked battery (13.49 V)
- checked leaf wetness [standard] sensors (new program needed)*
- checked pyranometer (adjusted level)
- checked soil sensor cables (good)
- checked solar panel (20.27 V)
- checked tipping-bucket rain gauge (adjusted level)
- checked wind vane (properly aligned)
- cleaned atmp/relh sensor and radiation shield
- cleaned pyranometer
- cleaned solar panel
- replaced anemometer (bearings bad)
* site does not include a canopy sensor
- routine site maintenance
- routine site maintenance, including:
- modem update
- routine maintenance, including:
- replaced leaf wetness (standard) sensor [237 -> LWS]*
- NOTE: updated logger program is needed
* site does not include a canopy sensor
- routine site maintenance
- replaced logger (CR10X -> CR1000)
- added PakBus modem
- loaded logger program: lin-bbac
- replaced wind sentry (i.e. direction/speed)
- routine station / site maintenance
- annual station / site maintenance
- routine maintenance
- annual maintenance
- manually reset logger clock
- replaced logger battery
- replaced logger battery
- cleared snow/ice from solar panel
- annual maintenance and weed removal
- Field team replaced solid-state relay to correct
communication failure.
- Live updates resumed at 16:10
- routine annual maintenance, including:
- cleaned air temp / rh sensor
- replaced anemometer (wind speed)
- Moved data-collection to new LoggerNet server
- Loaded logger program: ABCF (hourly cycle)
- Loaded Logger Program "ABCW" (3-hour collection cycle)
- Routine maintence, including:
- weed/grass removal
- solar panel cleaned
- Data Check and Database Update...
- "live" updates reactivated
- Broadband Modem Replaced.
- Loaded MAWN Program - ABCF (hourly collection cycle) [0008]
- Loaded MAWN Program - ABCW (3-hour collection cycle) [0007]
- General station maintenance and system checks, including:
- Tipping-bucket rain gauge test (faulty pcpn data
that was introduced was removed on 06/08/09)
- General station maintenance and system checks, including:
- Soil Moisture sensors now installed vertically:
- MSTR 0: profile of depth = 0 - 12"
- MSTR 1: profile of depth = 12 - 24"
- Work was done approx: 1230 - 1250 (Day=150)
- Replaced Datalogger Battery (sm)
- Fixed Tipping-Bucket Rain gauge installation. Was
off the mount and buried in the snow. Not sure how
long the gauge has been off the mount (sm)
- Switched from land-line modem to wireless modem (sm)
- Setup LoggerNet data-collection. Loaded MAWN
program (ABCF) [hourly collection schedule] (jb)
- Loss of battery voltage seemed to have caused the MAWN
program to be wiped from memory (again). Was able to
connect at 11:30am this morning and reloaded the MAWN
program (MAWN1C).
Data was lost for the following time period:
02/21/08 01:00 - 02/22/08 11:20
- Loss of battery voltage overnight seemed to have caused
the MAWN program to be wiped from memory. Was finally
able to connect at 4:00pm this afternoon and reloaded
the MAWN program (MAWN1C).
Data was lost for the following time period:
02/19/08 00:40 - 02/20/08 16:00
- Bad phone line which was causing telecommunication failure
has been repaired. This problem caused a temporary outage
in communication with the Linwood MAWN station, but there
was no loss of data.
- Telecommunication troubles corrected. Faulty phone
line - corrected by use new pair of wires within
the phone line.
- Data logger and battery replaced. This changed caused
data to be lost for the following time period:
08/10/04 (day =223) 17:15 - 08/12/04 (day=225) 12:05
- Rewired Temperature/Relative Humidity Sensor (HMP45C). The
previous connection seemed to draw too much power.
- Communication and data downloads resumed at 12:30.
First report: August 07, 2004 - 00:05 (Day=220))
Notes:
- datalogger program: MAWN1C (CS616, HMP45C)
Additional Station Needs:
- phone line