Enviro-weather, formerly Michigan Automated Weather Network

mcbain — Maintenance Reports

Download maintenance log

: Station / Logger Maintenance [1110]

- data-collection troubleshooting, including:

- replaced logger

- loaded logger program "mcb-bbad.cr1" (1140)

- routine maintenance, including:

- checked anemometer (good)

- checked battery (good)

- checked soil sensors (good)

- checked tipping-bucket rain gauge (good)

- checked wind vane

- checked / cleaned atmp/relh sensor [HMP45] (good)

- checked / cleaned leaf wetness [standard]

- checked / cleaned pyranometer (good)

- checked / cleaned atmp/relh radiation shield

- cleaned solar panel

- weed removal / trimmed grass

: Station / Logger Maintenance [1225]

- communcation troubleshooting:

- cleaned enclosure (remove excess moisture)

- re-wired 12V relay

- reloaded logger program "mcb-bbad.cr1" (1331)*

- routine site maintenance, including:

- checked anemometer (good)

- checked tipping-bucket rain gauge (good)

- checked wind vane (good)

- checked / cleaned leaf-wetness [standard]

- checked / cleaned pyranometer

* data-collection issues resurfaced at: 05/26/2026 2200...

...data-collection fails before hourly data is collected.

: Logger / Station Maintnenace [1404]

- loaded logger program: mcb-bbad.cr1* (237 -> LWS-L)**

* supports "maintenance mode"

** sensor replaced: 08/20/2020 (no canopy)

- cleaned-up previously collected data

: Station / Logger Maintenance [1200]

- resolved logger communication / clock issues

: Station Maintenance [1400]

- routine site maintenance

: Station / Logger Maintenance [1750]

- routine site maintenance

- repaired loose battery cable

- reset / power cycle logger

: Station Maintenance [1210]

- routine site maintenance

- installed updated modem

: Station Maintenance [1345]

- routine site maintenance, including:

- leaf wetness sensor upgrade (237 -> LWS)*

* there is no canopy sensor

: Station Maintenance [1310]

- routine site maintenance

: Logger / Station Maintenance; [1635]

- installed directional antenna

- corrected clock on logger

: Logger / Station Maintenance [1135]

- replaced logger (CR1000 -> CR1000)

- added PakBus modem

- loaded logger program: bbc-bbab

: Station Maintenance [1240]

- routine station / site maintenance

: Station/Logger Maintenance [1900]

- annual station / site maintenance

- reinstalled tipping-bucket rain gauge

: Station Maintenance [1530]

- routine maintenance

: Station Maintenance [0002]

- loaded logger program "mcb-bbaa"

: Station Maintenance [1225]

- annual maintenance, including:

- replaced atmp/relh (HC2S3 -> HMP45C)

: Station Maintenance [0006]

- loaded logger program "mcb-bbba"

: Station Maintenance [1730]

- replaced AIR TEMP/RELH sensors (HMP45C -> HC2S3)

- sensor connected to "continous" power

: Station Maintenance: [????]

- annual maintenance and weed removal

: System Maintenance [1103]

- moved data-collection to new LoggerNet server

- loaded logger program "bbaa-mcb"

: Station Maintenance [1350]

- Replaced Modem

: Station Maintenance [0006]

- Loaded updated Logger Program BBAA-MCB. Logger now

set to collect on a 30-minute cycle from Apr - Sep.

: Station Online

- Station added to MAWN web site.

: Data Collection Enabled

- Data Collection and Data Archive for new station begins:

First data report: May 21, 2009 - 00:05 (Day=141)

: Station Maintenance

- Established telecommunication between station cell-modem and

data collection PC/server on campus.

- Loaded MAWN Program: BBC-MCB

B => CR1000

B => CS616

C => Broadband Cell Modem (IP)

MCB => Station ID (McBain)

- Now able to collect raw weather data.