: Station Maintenance [1300]
- communication troubleshooting:
- reset logger / modem*
* did not correct the outage immediately, but the
communication did resume at 06/27/2023 2150 EDT
without explanation (possible cell-provider issue)

- communication troubleshooting:
- reset logger / modem*
* did not correct the outage immediately, but the
communication did resume at 06/27/2023 2150 EDT
without explanation (possible cell-provider issue)
- routine site maintenance, including:
- checked anemometer (good)
- checked atmp/relh sensor (good)
- checked battery (13.54V)
- checked pyranometer (adjusted level)
- checked soil sensor cables (good)
- checked solar panel (20.67V)
- checked tipping-bucket rain gauge (good)
- checked wind vane (properly aligned)
- cleaned atmp/relh sensor and radiation shield
- cleaned battery terminals
- cleaned solar panel
- cleaned tipping-bucket rain gauge
- tested leaf wetness sensor [standard] (good)*
* site does not include a canopy sensor
- loaded logger program: nwm-bssd.cr6
- marks current canopy leaf wetness as missing
- removed all canopy data back to 07/27/2015 10:35
- routine site maintenance, including:
- checked anemometer (bearings good)
- checked soil sensor cables (good)
- checked tipping-bucket rain gauge (adjusted level)
- checked wind vane (properly aligned)
- checked / cleaned pyranometer (adjusted level)
- checked / tested battery
- checked / tested leaf wetness (standard)*
- cleaned HygroVue (atmp/relh) radiation shield
- cleaned battery box
- cleaned solar panel
* site does not include a canopy leaf wetness sensor
- logger program change to ignore canopy data is needed
- routine site maintenance, including:
- checked anemometer (bearings good)
- checked pyranomter (level)
- checked soil sensor cables (good)
- checked tipping-bucket rain gauge (adjusted level)
- checked wind vane (properly aligned)
- checked / cleaned solar panel
- checked / tested battery
- checked / tested leaf wetness (standard)*
- cleaned battery box
- cleaned HygroVue (atmp/relh) radiation shield
* site does not include a canopy leaf wetness sensor
- logger program change to ignore canopy data is needed
- replaced faulty CR6 logger
- loaded logger program: nwm-bssb.cr6*
* supports "maintenance mode"
- routine site maintenance
- loaded logger program: nwm-bssb.cr6*
- wind direction fix
* supports "maintenance mode"
- loaded logger program: nwm-bssb.cr6*
- wind direction fix
* supports "maintenance mode"
- routine site maintenance, including:
- modem update
- loaded logger program: nwm-bssb.cr6*
* supports "maintenance mode"
- loaded logger program: nwm-bssb
- replaced logger (CR1000 -> CR6)
- added PakBus modem
=======================================================================i======
- replaced faulty solid-state relay
- reload logger program: nwm-bbbbC
- supports switch of HC2S3 from SW12V to 12V
- Switched Air Temp/RH sensor (HC2S3) to "continous" power
- Station upgraded with new logger and serveral new sensors.
- loaded logger program "nwm-bbbbC"
- Due to upgrade, station was offline for the following:
07/27/2015 (d=208) 1035 - 07/27/2015 (d=208) 1225
- the "live" data updates were able to resume at:
07/28/2015 (d=209) 1630
- moved data-collection to new LoggerNet server
- loaded logger program "bbaaC-nwm"
- Loaded updated Logger Program BBAA-NWM. Logger now
set to collect on a 30-minute cycle from Apr - Sep.
- Loaded updated MAWN Program: BBC-NWM (hourly
collection cycle even during the winter)
- Repaired "Soil Moisture A". Station powered-off
between 9:10 - 9:13 to make repairs/connections.
- Changed Daily Battery Voltage to 24-hour Observered
Minimum Voltage.
- Added Hourly Standard Deviation of Wind Direction
- Reactivate "live" updates
- Loaded MAWN Program: BBC-NWM
- Moved station to new location:
- Replaced old logger with newer CR1000
- Due to move, no data during following time period:
11/14/2011 (d=318) 1005 - 11/14/2011 (d=318) 1245
- Loaded MAWN Program - AACF (60-minute collection cycle)
- Recent collection/communication failure lead to loss of
data. Estimated "hourly" and "daily" air temperature
values were added into the MAWN database for the following
time period:
07/04/2011 (d=185) 1900 - 07/11/2011 (d=192) 1500
- Loaded MAWN Program AACS (30-minute power/collection
cycle). Data-collection now controlled by LoggerNet
server on main campus of Michigan State University.
- Converted communication with station to wireless broadband
due to recent failure of remote data-collection (PC208W
software).
- The Solar Radiation sensor was replaced in 2005. However,
for a period of time in May 2005, faulty Solar Radiation
data still existed in the MAWN database.
Solar Radiation for the following time period was removed
from the aarchived raw data file as well as removed from
the MAWN database:
05/06/05 (d=126) 2000 - 05/26/05 (d=146) 1400
- Repairs needed after recent thunderstorm:
- short haul modem was replaced
- power to datalogger was reset
- MAWN program (MAWN1B) was reloaded.
- Recent outage led to loss of data for the following
time period:
08/12/07 (day=224) 06:35 - 08/13/07 (day=225) 10:45
Although daily data for 08/12 was lost, an entry was added
to the database to report the 1.31" of rain that was manually
observed and recorded at the NWMHRS station.
- Current battery was not holding charge, so it was
replaced with another battery this morning.
- Battery was replaced.
- Installed Soil Moisture B:
- sensor model: CS615
- depth: 25 cm
- Reinstalled Soil Moisure A:
- sensor model: CS615
- depth: 10 cm
- Checked all other sensors.
- Routine maintenance and cleaning.
- Replaced Soil Temperature Sensors
- Replaced Solar Radiation Sensor
- Removed/Checked/Reinstalled Soil Moisture Sensor (sensor A).
Still Missing 2nd Soil Moisture Sensor (sensor B).
- Cleaned Air Temp/Relative Humidty Sensor
- Cleaned and Reconnected All Grounding Cables
- Daylight Savings Time Started on Day=97, Time=200.
- Time of Obs were modified by one hour (forward)
from Day=97, Time=200 through Day=98, Time=1215.
- Daylight Savings Time Ended on Day=301, Time=200.
- Time of Obs were modified by one hour (subtracted)
from Day=301, Time=200 through Day=301, Time=950.
??/??/????: Station Installed.