: Logger / Station Maintenance (FS#3702) [1100]
- logger status showing strange start time (01/25/2038)
- reloaded logger program "obl-bbcb.cr1" to reset

- logger status showing strange start time (01/25/2038)
- reloaded logger program "obl-bbcb.cr1" to reset
- logger OS downgrade (32.07 -> 32.05)*
- replaced internal battery
* v32.07 resets logger after manual LoggerNet connection.
- logger support, including:
- installed new comm cable
- installed new 12V relay
- replaced modem
- upgraded logger OS (32.07)
- routine site maintenance, including:
- checked air temperature / relative humidity (good)
- checked anemometer (good)
- checked battery (13.99 V)
- checked pyranometer (good)
- checked soil sensors (taped up some minor damage)
- checked wind vane (good)
- checked / cleaned leaf wetness [standard] (good)
- ehecked / cleaned leaf wetness [canopy] (good)
- cleaned radiation shield (HMP155)
- cleaned solar panels
- weed removal / trimmed grass
- routine site maintenance, including:
- checked anemometer (good)
- checked battery (13.76 V)
- checked pyranometer (good)
- checked soil sensors (good)
- checked wind vane (good)
- checked / cleaned air temp / relative humidity (good)
- checked / cleaned leaf wetness [standard] (good) *
- checked / cleaned leaf wetness [canopy] (good)
- cleaned radiation shield (HMP155)
- cleaned solar panels
- weed removal / trimmed grass
* may need to replace standard leaf wetness sensors [lws0] soon
- routine site maintenance, including:
- checked air temp / relative humidity (good)
- checked battery (13.52 V)
- checked anemomter (good)
- checked power source [solar] connection (good)
- checked soil sensors (good)
- checked wind vane (good)
- checked / cleaned leaf wetness [standard] (good)
- checked / cleaned leaf wetness [canopy] (good)
- checked / cleaned pyranometer (good)
- checked / cleaned solar panel (good)
- checked / cleaned tipping-bucket rain gauge (good)
- cleaned radiation shield (HMP155)
- weed removal / trimmed grass
- routine site maintenance, including:
- checked battery (good)
- checked leaf wetness [canopy] (good)
- checked leaf wetness [standard] (good)
- checked soil sensors (good)
- checked tipping-bucket rain gauge (adjusted level)
- checked pyranometer (good)
- cleaned solar panel
- replaced atmp/relh sensor (hmp45c -> hmp155)*
- replaced wind sentry (i.e. anemometer, wind vane)
- weed / grass removal around station
* loaded logger program: obl-bbcb.cr1
- supports "maintenance mode"
- supports "hmp155" sensor (atmp/relh)
- routine station maintenance, including:
- update modem
- replaced faulty anemometer (i.e. wind direction)
- cleaned / tested leaf wetness sensor (standard mount)
- cleaned / tested tipping bucket rain gauge
- Station added to Enviroweather/MAWN database system
- Data Collection and Data Archive for new station begins:
First data report: Sept 03, 2020 (d=247) 00:05
- Loaded MAWN Program: obl-bbab.cr1
obl => Station Id (onekama)
b = MI (state network)
b = CR616 (soil moisture)
a = HMP45C (air temp / rh)
b = LWS-L (leaf wetness) [both]
cr1 => CR1000 (logger / logger program type)
- Now able to collect raw weather data.
- Established telecommunication between station cell-modem
and data-collection PC/server on campus.
- station relocated from former Bear Lake (blk) site
- station setup/activated at field site