spartanorth — Maintenance Reports
Download maintenance log
: Station Maintenance [9010]
- routine site maintenance, including:
- checked anemometer (good)
- checked battery (good)
- checked pyranometer (ajusted level)
- checked wind vane (properly aligned)
- checked / cleaned solar panel
- checked / tested leaf wetness (standard)*
- checked / tested tipping-bucket rain gauge (adjusted level)
- cleaned battery box
- replaced HygroVue19 (atmp/relh)
* site does not include a canopy leaf wetness sensor
: Station Maintenance [1040]
- routine site maintenance (visual inspection only)
: Station Maintenance [1030]
- routine site maintenance
: Station / Logger Maintenance [1050]
- routine site maintenance
- modem upgrade
: Station Maintenance [1145]
- routine station maintenance
- installed new leaf wetness mount
: Logger Maintenance [1326]
- power cycle (modem & logger)
: Station Maintenance [1200]
- repaired faulty atmp/dwtp/relh (CS650) sensor
: Station Maintenance [1400]
- install soil sensors (i.e. soil temp/moisture)
: Station Online [1325]
- Station added to Enviroweather/MAWN database system
: Data Collection Enabled [1150]
- Data Collection and Data Archive for new station begins:
First data report: March 27, 2019 (d=086) 00:05
: Logger Setup [1130]
- Loaded MAWN Program: spn-bssd
spn => Station ID (spartanorth)
b => CR1000/MI (Logger/Site)
s => SDI-12 [CS650] (Soil Moisture)
s => SDI-12 [HygroVue10] (Temp/RH)
d => LWS-L (Leaf Wetness) [no canopy]
- Now able to collect raw weather data.
: Station Maintenance: [----]
- Established telecommunication between station cell-modem
and data-collection PC/server on campus.
: Station Setup [----]
- station setup/activated at field site