: Logger Maintenance [1035]

- replaced logger (CR1000 -> CR1000 / PakBus change)

- loaded logger program: stn-bbcb

: Logger Maintenance [0033]

- loaded logger program: stn-bbcb

: Logger Maintenance [1320]

- replaced logger (CR1000 -> CR1000)

- added PakBus modem

- loaded logger program: stn-bbcb

: Logger Maintenance [1203]

- loaded new logger program "stn-bbcb"

: Station Maintenance [1520]

- sensor maintenance:

- replaced atmp/relh (HMP45C -> HMP155A)

: Station Maintenance [1620]

- sensor maintenance:

- replaced faulty standard leaf wetness sensor (lws0)

- replaced faulty HMP46C (atmp/relh) sensor

: Logger Maintenance [1437]

- reloaded logger program "stn-bbab"

- hourly data table was not reporting prior to program load

: Station Maintenance [1545]

- annual maintenance

: Station Maintenance [1410]

- annual maintenance, including:

- replacement of canopy leaf wetness sensor (lws1)

- replacement of 2" soil temperature sensor (soil0)

: Station Maintenance [1120]

- replaced faulty logger battery (35 amp battery installed)

: Station Maintnenace [1245]

- annual maintenance

: Station Maintenance [1830]

- annual maintenance

: Station Maintenance [1545]

- repaired/reinstalled AIR TEMP/RELH sensor (HMP45C)

: Station Maintenance [1605]

- loaded logger program "stn-bbab"

: Station Maintenance [1245]

- replaced air temp/relh sensor (HMP155A -> HMP45C)

- sensor now connected to "continuous" power

: Station Maintenance [1245]

- Replaced ATMP/RELH sensor (HC2S3 -> HMP155A)

- Loaded new logger program (bel-bbcb)

: Station Maintenance [1130]

- replaced air temp/relative humidity sensor

: Station Maintenance [1230]

- replaced soil moisture A (0-12") sensor

: Data cleanup [1620]

- no explanation for it, but RH data was faulty for nearly a

three day period. All RH data was marked as MISSING for the

following:

05/09/2015 (d=129) 0615 - 05/11/2015 (d=131) 2240

: Station Maintenance: [????]

- did not replace AIR TEMP/RH sensor, but did adjust

mounting and removed electrical tape that was attached.

- checked and tightened all wire connections

- weed removal

: Station Maintenance [1215]

- Corrected loose communication cable

- Corrected leaf wetness sensors:

- corrected faulty wiring

- reinstalled sensors in proper orientation

- leaf A installed on tripod

- leaf B installed on tripod (not in canopy at this time)

- NOTE: all leaf wetness prior to the following should be

ignored:

04/20/2014 (d=110) 1400

- added estimated MAX/MIN Air Temps for 04/17/2015

: Station Online [1230]

- Station added to Enviroweather/MAWN Web Site

: Data Collection Enabled [1600]

- Data Collection and Data Archive for new station begins:

First data report: October 23, 2014 (Day=296) 0005

: Station Installed [1700]

- Station installed at station field site

: Station Maintenance [1630]

- Established telecommunication between station cell-modem

and data-collection PC/server on campus.

: Station Setup [1630]

- Loaded MAWN Program: BBBB-STN

B => CR1000/MI (Logger/State)

B => CS616 (Soil Moisture)

B => HC2S3 (Temp/RH)

B => LWS-L (Leaf Wetness)

STN => Station ID (Standale)

- Now able to collect raw weather data.