Enviro-weather, formerly Michigan Automated Weather Network

emmett — Maintenance Reports

Download maintenance log

: Logger / Station Maintenance [1606]

- loaded logger program: emt-bbad.cr1* (237 -> LWS-L)**

* supports "maintenance mode"

** sensor replaced: 07/21/2020 (no canopy)

- cleaned-up previously collected data

: Logger / Station Maintenance: [----]

- power / charging system troubleshooting, including:

- replaced logger battery

- routine site maintenance, including:

- checked anemometer (good)

- checked battery (12.65 V)

- checked leaf wetness [standard] sensor (program update needed)*

- checked pyranometer (adjusted level)

- checked soil sensors (good)

- checked solar panel (18.91 V, adjusted orientation)

- checked tipping-bucket rain gauge (good)

- checked wind vane (adjusted orientation)

- cleaned atmp/relh sensor and radiation shield

- cleaned battery terminals

- cleaned tipping-bucket rain gauge

* site does not include canopy sensor

: Station Maintenance [1020]

- routine site maintenance, including:

- checked anemometer (good)

- checked battery (13.65 V)

- checked leaf wetness [standard] sensor (program update needed)*

- checked pyranometer (adjusted level)

- checked soil sensors

- checked solar panel (19.22 V)

- checked tipping-bucket rain gauge (adjusted level)

- checked wind vane (properly aligned)

- cleaned atmp/relh sensor and radiation shield

- cleaned battery terminals

- cleaned solar panel

- cleaned tipping-bucket rain gauge (removed debris from funnel)

* site does not include a canopy sensor

: Station Maintenance [0955]

- routine site maintenance, including:

- checked anemometer (good)

- checked battery box (good)

- checked leaf wetness [standard] sensor (program update needed)*

- checked pyranometer (adjusted level)

- checked soil sensors (good)

- checked solar panel (19.22 V)

- checked tipping-bucket rain gauge (adjusted level)

- checked wind vane (properly aligned)

- cleaned atmp/relh sensor and radiation shield

- cleaned solar panel

- cleaned tipping-bucket rain gauge ()

* site does not include a canopy sensor

: Station Maintenance [0955]

- routine site maintenance, including:

- checked anemomter (replaced bearings)

- checked battery (13.2 V)

- checked battery box (good)

- checked leaf wetness [standard] sensor (program update needed)*

- checked pyranometer (adjusted level)

- checked soil sensors (good)

- checked solar panel (17.86 V)

- checked tipping-bucket rain gauge (adjusted level)

- checked wind vane (properly aligned)

- cleaned atmp/relh sensor and radiation shield

- cleaned solar panel

- cleaned tipping-bucket rain gauge

- weed removal

* site does not include a canopy sensor

: Station Maintenance [1150]

- routine site maintenance

: Station Maintenance [1140]

- routine site maintenance, including:

- installed updated modem

: Station Maintenance [1045]

- routine maintenance, including:

- replaced leaf wetness (standard) sensor [237 -> LWS]*

- NOTE: updated logger program is needed

* site does not include a canopy sensor

: Logger / Station Maintenance [1200]

- station properly reinstalled

- data-collection resumed

: Logger / Station Maintnenace [1105]

- station was moved from original location and is no

longer properly installed...

...station is disabled until further notice

: Logger / Station Maintenance [1445]

- replaced logger (CR10X -> CR1000)

- added PakBus modem

- loaded logger program: emt-bbac

: Station Maintenance [1015]

- clear obstructions from tipping-bucket rain gauge

: Station Maintenance [1245]

- routine station / site maintenance

: Station Maintenance [1130]

- annual station / site maintenance

: Station Maintenance [1325]

- annual maintenance

: Station Maintenance [1110]

- replaced leaf wetness (standard) [LEAF0]:

- LWS-L -> 237

: Station Maintenance [1235]

- annual maintenance

- replaced leaf wetness (standard) [LEAF0]:

- 237 -> LWS-L

- NOTE: program assumes 237 sensors

- NOTE: this site doesn't have canopy [LEAF1] sensor

: Station Maintenance [1200]

- cleaned precipitation bucket and rechecked installation

: Station Maintenance [1150]

- replaced logger battery

: Station Maintenance [1150]

- replaced logger battery

- cleared snow/ice from solar panel

: Station Maintenance [1515]

- routine station maintenance, including:

- cleaned tipping-bucket rain gauge

: Station Maintenance [1407]

- Moved data-collection to new LoggerNet server

- Loaded logger program: ABCF (hourly cycle)

: Station Maintenance [1500]

- Battery / Power Issues resolved.

- Due to recent power issues, some data was lost during

the following period:

10/18/2013 (d=291) 0705 - 11/05/2013 (d=309) 1500

: Station Maintenance [2400]

- Precipitation bucket was clogged. Data removed for the

following period:

04/11/2013 (d=101) 0005 - 04/26/2013 (d=116) 2400

: Station Maintenance [1200]

- Battery replaced.

- recent battery troubles has lead to periods of

"missing" data.

: Station Maintenance [1135]

- Routine Spring Maintenance, including:

- Weed-Control (removal and herbicide application)

- Debris removed from solar panel

: Data Quality [1200]

- Performed data checks/removed faulty data introduced

due to recent battery issues.

- Although several "low battery" were reported during the

Nov 2010 - Feb 2011 time period, data was only lost

during the following:

01/02/2011 (d=002): 0105 - 1000

01/02/2011 (d=002): 2305 - 2400

01/03/2011 (d=003): 0005 - 1000 (including daily summary)

01/17/2011 (d=017): 0705 - 1000 (including daily summary)

: Station Maintenance

- Battery replaced

: Station Maintenance: [16:15]

- Have not been able to connect since 14:00 on 06/04/09.

- Replaced Cell-IP modem - station back online.

: Station Maintenance

- General station maintenance and system checks. [12:00]

: Station Maintenance

- General station maintenance and system checks, including:

- cleaning of precipitation tipping bucket (required

removal of faulty data).

- Soil Moisture sensors now installed vertically:

- MSTR 0: profile of depth = 0 - 12"

- MSTR 1: profile of depth = 12 - 24"

- Work was done approx: 1015 - 1100 (Day=228)

: Data Management (jb)

- It was determined that soil temp 0 has been reporting faulty

data since the station was brought online. All Soil Temp 0

(2" soil temp) between the following dates/times has been

removed:

Dec 20, 2006 [00:00] - Apr 26, 2007 [16:00]

: Station Maintenance

- General station maintenance and system checks.

- Soil Temp 0 sensor was replaced.

- Soil Temp 1 sensor was replaced.

- Work was done approx: 15:30 - 16:00 (Day=116)

: Station Online

- Station added to MAWN web site.

: Data Collection Enabled

- Data Collection and Data Archive for new station begins:

First data report: Dec 20, 2006 - 00:05 (Day=354)

: Station Maintenance

- Established telecommunication between station cell-modem and

data collection PC/server on campus.

- Loaded MAWN Program: MAWN_ABCF

- Now able to collect raw weather data.

: New Station Installed

- Former "goodells" station moved and setup at Emmett.

Notes:

- soil temp A (2") needs to be replaced.

Additional Station Needs: