: Logger Maintenance [1202]
- loaded logger program: ent-bbcbS.cr1*
- both standard and canopy leaf wetness sensors
* supports "maintenance mode"

NOTE: Station is located near center-pivot irrigator. The
precipitation bucket is covered while irrigating, but
care must be taken when using moisture-related variables
such as precipitation and soil moisture.
- loaded logger program: ent-bbcbS.cr1*
- both standard and canopy leaf wetness sensors
* supports "maintenance mode"
- routine site maintenance
- routine site / station maintenance
- updated modem
- replaced wind sentry (i.e. wind speed / direction)
- routine site maintenance, including:
- replaced leaf wetness sensor (standard mount)
- replaced faulty soil temperature sensor (10cm)
- replaced logger (CR1000 -> CR1000)
- added PakBus modem
- loaded logger program: ent-bbcbS
- replaced faulty atmp/relh sensor (1.5m)
- checked / tested tipping-bucket rain gauge
- Soybean Inversion Study Upgrade, including:
- logger upgrade (CR10X -> CR1000)
- install new ATMP/RELH sensor @ 45cm
- install new ATMP/RELH sensor @ 3m
- replace leaf wetness sensors (237 -> LWS-L)
- load new logger program "ent-bbcbS"
- general maintenance / cleanup
- load logger program "mawn_adcf"
- replaced faulty ATMP/RELH sensor (HMP45C -> HMP155A)
- annual maintenance
- annual maintenance
- cleared precipiation bucket
- annual maintenance and weed removal
- annual maintenance and weed removal
- loaded logger program "mawn_abcf" (hourly collection cycle)
- loaded logger program "mawn_abcw"
- moved data-collection to new LoggerNet server
- loaded logger program "mawn_abcf"
- routine annual maintenance
- General station maintenance and system checks, including:
- Cleaning of Leaf Wetness Sensor (Standard Mount)
- Replacement of Anemometer (i.e. Wind Speed Instrument)
- Replaced dead battery
- NOTE: Due to faulty battery, data was lost during the
following time period:
06/14/2012 (d=166) 1420 - 06/20/2012 (d=172) 1200
- Replaced faulty solar panel/battery cable/connection
- Moved station approx. 30-feet to avoid irrigation radius.
- NOTE: data prior to 06/20/2012 1200 may contain faulty
precipitation data due to irrigation.
- Replaced Modem
- Station moved (approx. 500-ft to NW of previous
location.
- Tipping-bucket rain gauge replaced with a new unit
- Routine Spring Maintenance, including:
- Precipitation Bucket Cleaned
- Weed-Control Applied
- Soil Temp 0 (2") checked and calibrated
- Soil Temp 1 (4") replaced
- Routine maintence/sensor checks
- Loaded MAWN Program - ABCF (hourly collection cycle) [0006]
- Loaded MAWN Program - ABCW (3-hour collection cycle) [0004]
- General station maintenance and system checks, including:
- Tipping-bucket rain gauge test (faulty pcpn data
that was introduced was removed on 06/08/09)
- General station maintenance and system checks, including:
- Soil Moisture sensors now installed vertically:
- MSTR 0: profile of depth = 0 - 12"
- MSTR 1: profile of depth = 12 - 24"
- Work was done approx: 1600 - 1700 (Day=141)
- Loaded MAWN Program: MAWN_ABCF (00:05)
- Communication converted to broadband cell-modem:
- Broadband Cell modem installed.
- Datalogger Program "mawn_abcs" Loaded and Compiled
- Data Collection Configured To Upload Every 30 minutes.
- General Station Maintenance and System Checks:
- weed removal and application of Round-Up above soil temps
- sensor placement checked
- anemometer bearings checked
- replaced temp/rh sensor (HMP45C)
- rain gauge relocated away from center-pivot irrigation
- Work was done approx: 11:05 - 11:30 (Day=223)
- Tipping Bucket Rain Gauge Calibrated Between 13:00
and 14:00 (Day=195)
- Data Collection and Data Archive for new station begins and
now made available via the MAWN website:
First data report: Apr 08, 2004 - 00:05 (Day=099)
Notes:
- leaf wetness B (canopy) - still needs to be installed.
- Data Logger Program Loaded: MAWN1B
Additional Station Needs: