: Logger Maintenance [1033]
- loaded logger program: esc-bbsd.cr1*
* supports HMP45C -> HygroVue10 change (atmp/relh)
NOTE: sensor change / data cleanup still needed

- loaded logger program: esc-bbsd.cr1*
* supports HMP45C -> HygroVue10 change (atmp/relh)
NOTE: sensor change / data cleanup still needed
- routine site maintenance, including:
- adjusted solar panel
- checked atmp/relh (good)
- checked leaf wetness [standard] (good)
- checked pyranometer (good)
- checked soil sensors (good)
- checked tipping-bucket rain guage (good)
- checked voltages: battery (12.53V), solar panel (24.15V)
- checked wind speed / wind direction (good)
- cleaned atmp/relh radiation shield
- cleaned leaf wetness*
- cleaned solar panel
- updated cell modem OS:
- added diversity antenna
- added new com cable
- removed relay
- NOTE: modem stays on continuously**
- weed removal
* site does not include a canopy sensor
** may want to increase data-collection to every 15 minutes.
- loaded logger program: esc-bbad.cr1 (237 -> LWS-L)*
* supports "maintenance mode"
* sensor replaced: 03/22/2024
* cleaned-up previously collected data
- routine site maintenance, including:
- checked atmp/relh (good)
- checked battery voltages (all good)
- checked soil sensors (all good)
- checked station tripod (good)
- cleaned atmp/relh radiation shield
- replaced leaf wetness [standard] (237 -> LWS)* **
- replaced tipping-bucket rain gauge
- replaced wind sentry (wind speed / wind direction)
* site does not include a canopy sensor
** updated logger program needed.
- resolved power issues
- A/C power interrupted due to tripped GFCI circuit
which needed to be reset
- routine site maintenance, including:
- checked backup battery (12.83 V)
- checked leaf wetness [standard] (good)*
- checked pyranometer
- checked soil sensors
- checked tipping-bucket rain gauge (leveled and cleaned)
- checked wind vane (adjusted orientation)
- replaced anemometer
- weed removal
* station does not include a canopy sensor
- checked / cleaned tipping-bucket rain gauge
- checked / cleaned tipping-bucket rain gauge
- replaced logger (CR10X -> CR1000)
- added PakBus modem
- loaded logger program: esc-bbac
- some on-site electrical work was performed, but did not
impact most sensors, but some faulty precipitation data
appears to have been introduced (was removed on 10/03/18)
- 120VAC power line repaired
- solar panel charging system repaired
- replaced solar panel charge system with 120VAC power
supply.
- replaced faulty battery
- replaced faulty battery
- logger battery replaced
- loaded logger program "mawn_abcf" (hourly collection cycle)
- loaded logger program "mawn_abcw"
- faulty battery replaced
- Moved data-collection to new LoggerNet server
- Loaded logger program: ABCF (hourly cycle)
- Logger battery replaced.
- Loaded Logger Program "ABCW" (3-hour collection cycle)
- Replace wireless broadband modem
- Added "hourly battery voltage" to hourly database table
- Routine maintence, including:
- removed debris from tipping-bucket rain gauge
- Installed wireless broadband modem (Cell-IP).
- Loaded MAWN Program "ABCF" (hourly power cycle).
- Non-responding soil moistures sensors corrected. However,
soil moisture data is not available during the following
time period:
07/21/2008 (d=203) 16:00 - 03/11/2009 (d=070) 16:00
- "Winterized" the tipping-bucket precipitation gauge (the
frozen precipitation extension filled with anti-freeze).
- Data logger and short-haul modems were replaced at 15:45.
- Data collection restarted.
- Due to recent logger failure, data was lost for the
following time period:
07/07/08 (d=189) 22:05 - 07/21/08 (d=203) 1535
- General Station Maintenance (Calibration)
- tests indicate that the tipping-bucket rain gauge may
be underestimating precipitation amounts.
- tipping-bucket was calibrated this morning, but
it appears that additional testing may be needed
(number of clicks not equal to expected amount)
- precipitation values in the database may need to be
adjusted (values may be 20% lower than what was
actually observed).
- General Station Maintenance and System Checks:
- mounted precipitation bucket on new post
- cleaned/checked precipitation bucket
- reinstalled soil sensors
- cleaned/checked entire system
- New set of FTP scripts installed to work with PC208W. Should
elimiate need to make local updates (truncate) raw data file.
Two new scripts installed/configured:
mawnftp: (ftp recently collected weather data)
mawncopy: (creates backup of raw data file, truncates
original file, transfers backup to server)
- Work was done approx: 13:30 - 15:00 (Day=275)
- General Station Maintenance and System Checks:
- Replaced Anemometer Bearings [~ 12:45].
- Checked Temperature/Relative Humidity Sensor (HMP45C). No need
to replace as this sensor was calibrated in 03/2004.
- Checked Tipping Bucket Rain Gauge [12:30].
- Repaired Station Grounding. Connection was loose at grounding
rod and grounding wire inside datalogger was not connected. Both
were corrected.
- Work was done approx: 12:20 - 12:50 (Day=275)
- Site Visit/Spring Maintenance - Sensor Check: All OK
First report: Jun 17, 2003 - 00:05 (Day=168)
Notes:
- leaf wetness B (canopy) - still needs to be installed.
- Data Logger Program Loaded: MAWN1C
Additional Station Needs: