Download maintenance log

: Station Maintenance [1155]

- station maintenance, including:

- replaced faulty leaf wetness [standard] sensor*

- weed removal

* site does not include a canopy sensor

: Logger / Station Maintenance [1603]

- loaded logger program: hdn-bbcd.cr1* (237 -> LWS-L)**

* supports "maintenance mode"

** sensor replaced: 07/08/2020 (no canopy)

- cleaned-up previously collected data

: Station Maintenance [1300]

- routine site maintenance, including:

- checked anemometer (good)

- checked battery (13.55 V)

- checked leaf wetness sensor (program change needed)*

- checked pyranometer (adjusted level)

- checked soil sensors (good)

- checked solar panel (19.5 V)

- checked tipping-bucket rain gauge (adjusted level)

- checked wind vane (properly aligned)

- cleaned atmp/relh sensor and radiation shield

- cleaned solar panel

* site currently does not support canopy leaf wetness

: Station Maintenance [1140]

- routine site maintenance, including:

- checked anemometer (good)

- checked battery (13.40 V)

- checked leaf wetness sensor (program change needed)*

- checked pyranometer (adjusted level)

- checked soil sensors (good)

- checked solar panel (18.62 V)

- checked tipping-bucket rain gauge (cleaned funnel)

- checked wind vane (properly aligned)

- cleaned atmp/relh sensor and radiation shield

- cleaned solar panel

* site currently does not support canopy leaf wetness

: Station Maintenance [1340]

- routine site maintenance, including:

- checked anemometer (good)

- checked battery (13.06 V)

- checked leaf wetness sensor (program change needed)*

- checked pyranometer (good)

- checked soil sensors (good)

- checked solar panel (21.20 V)

- checked tipping-bucket rain gauge (good)

- checked wind vane (properly aligned)

- cleaned atmp/relh sensor and radiation shield

- cleaned battery box

- cleaned solar panel

- weed removal

* site currently does not support canopy leaf wetness

: Station Maintenance [1120]

- routine site maintenance, including:

- checked anemometer (good)

- checked battery (13.43 V)

- checked leaf wetness sensor (program change needed)*

- checked pyranometer (good)

- checked soil sensors (good)

- checked solar panel (18.52 V... adjusted alignment)

- checked tipping-bucket rain gauge (good)

- checked wind vane (properly aligned)

- cleaned atmp/rel sensor and radiation shield

- cleaned solar panel

- weed removal

* site currently does not support canopy leaf wetness

: Station Maintenance [1525]

- replaced anemometer (wind speed)

: Station Maintenance [1035]

- repaired wind vane

: Station Maintenance [1615]

- station / sensor repair (damage occurred 07/22/2021)

: Station Maintenance [1000]

- routine maintenance, including:

- tipping-bucket rain gauge repair

: Station Maintenance [1010]

- routine maintenance, including:

- modem replacement

: Station Maintenance [1345]

- routine maintenance, including:

- replaced leaf wetness (standard) sensor [237 -> LWS]*

- NOTE: updated logger program is needed

* site does not include a canopy sensor

: Station Maintenance [1415]

- routine maintenance, including:

- cleared obstruction from tipping-bucket rain gauge

: Station Maintenance: [----]

- cleared obstruction from tipping-bucket rain gauge

: Logger / Station Maintenance [0945]

- replaced logger (CR1000 -> CR1000)

- added PakBus modem

- loaded logger program: hdn-bbca

: Station Maintenance [1050]

- annual station / site maintenance

: Station Maintenance [0900]

- annual maintenance

: Station Maintenance [0005]

- loaded logger program "hdn-bbca"

: Station Maintenance [1230]

- replaced tipping-bucket rain gauge

- confirmed ATMP/RELH wired to continuous power

: Station Maintenance [1200]

- replaced faulty modem

- installed directional antenna

: Station Maintenance [1210]

- replaced faulty CR10/CR10X logger with CR1000 logger

- loaded new logged program "hdn-bbca"

- replaced faulty AIR TEMP/PH sensor (HMP45A -> HMP155A)

- replaced faulty LEAF WETNESS (standard sensor - "leaf0")

: Station Maintenance [2240]

- It appears the rain gauge obstruction may have been

removed. Unexplained precipitation that was reported

has since been removed from the database.

: Station Maintenance [1230]

- annual maintenance and weed removal

- unplugged precipitation bucket

- replaced leaf wetness sensors

: Station Maintenance [1030]

- replaced wind instruments

: Station Maintenance [0004]

- loaded logger program "mawn_abcf" (hourly collection cycle)

: Station Maintenance [1150]

- replaced logger battery

: System Maintenance [1005]

- loaded logger program "mawn_abcw"

: System Maintenance [1404]

- moved data-collection to new LoggerNet server

- loaded logger program "mawn_abcf"

: Station Maintenance [1600]

- replaced faulty wind vane

: Station Maintenance [0900]

- Replaced Anemometer (Wind Speed Sensor)

- Due to faulty sensor, wind speed data marked as "missing"

for following time period:

01/13/2013 (d=013) 2125 - 06/25/2013 (d=176) 0905

: Station Maintenance [1030]

- Replaced Modem

: Data Quality [1500]

- Due to recent sensor failure (e.g. ATMP/RH), all AMTP and

RH data reported durng the following time period were marked

as "missing":

08/22/2011 (d=234) 0140 - 09/09/2011 (d=252) 1415

: Station Maintenace [1415]

- Air Temp/RH has been reporting "junk" since early in the

day on 08/22/2011. Upon investigation, it was determined

that the TEMP/RH sensor had become disconnected. Proper

connection/installation at 2:15pm this afternoon.

: Station Maintenance [1120]

- Old CR10 datalogger was replaced with a CR10X

- Installed new battery

- Installed new power-supply

- MAWN program (ABCF) reloaded

- As of 03/02/2010 (d=061) at 13:00, station is back

online. However, due to recent logger failure data

was lost and is not available for the following time

period:

02/13/10 (d=044) 0605 - 03/01/10 (d=060) 1120

: Data Clean-up [1630]

- Faulty Temp/RH data was introduced into the MAWN

database prior to sensor replacement. Temp/RH

values that were recorded during the following

time period were marked as "missing":

09/08/09 (d=251) 00:40 - 09/11/09 (d=254) 10:35

: Station Maintenance [1035]

- Faulty Temp/RH Sensor was replaced.

- Precipitation bucket was cleared.

: Station Maintenance [1500]

- General station maintenance and system checks, including:

- Temp/RH sensor replacement

- Tipping-bucket rain gauge test.

: Station Maintenance

- Loaded MAWN Program - ABCF (60-minute power cycle) [0003]

: Station Maintenance

- Several recent hardware changes have not corrected the

communication trouble at Hudson. Sensor and logger

upgrade may be necessary.

*** The Hudson station will be down indefinitely **

: Station Maintenance

- Replaced power supply

- Added 2nd battery

- Replaced modem

- Due to the recent hardware failure, data was lost for

the following time period:

04/18/08 (d=109) 22:05 - 04/23/08 (d=114) 11:00

: Station Maintenance

- Datalogger was replaced for the second time this week

(early logger was not collecting any useful data). As

of 11:05, the replacement logger was collecting data.

- Will need to keep an eye on things for a few days to

determine if the replacement is working properly. Also,

need to monitor to determine if replacement of solid-state

relay continues to improve the "power-glitch" issue.

- Due to the logger replacements this week, data was

lost for the following time period:

04/05/08 (d=096) 21:05 - 04/18/08 (d=109) 11:00

: Data Cleanup (jb)

- Removed several data entries from raw data archive

and MAWN database that were introduced due to the

apparent short-circuiting issue that would sometimes

occur when the wireless modem was powered-on.

Due to the power issue, several data entries during

the following time period where faulty and were

removed from the data archive:

Aug 10, 2007 - Feb 22, 2008

Additional entries may need to be removed depending

on the results of the solid-state relay that was

installed on 02/23/2008.

: Station Maintenance (sm)

- Installed Solid-State Reply which will hopefully

correct short-circuit issue that occasionally

seems to occur when the wireless modem is powered

on.

: Station Maintenance (jb)

- Loaded MAWN Program: MAWN_ABCF (1-hr power cycle) [15:37]

: Station Maintenance: (bn)

- Communication converted to broadband cell-modem:

- Broadband Cell modem installed.

- Datalogger Program "mawn_abcs" Loaded and Compiled

- Data Collection Configured To Upload Every 30 minutes.

- General Station Maintenance and System Checks:

- Work was done approx: 11:15 - 12:00 (Day=204)

: Station Maintenance: (bn)

- General Station Maintenance and System Checks:

- weed removal and application of Round-Up above soil temps

- sensor placement checked:

- reburied soil temperature A (2")

- rebuired soil temperature B (4")

- anemometer bearings checked

- rain gauge checked for debris

- Work was done approx: 18:20 - 18:45 (Day=152)

: Data Quality (jtb)

- Several bad data values due to faulty TEMP/RH sensor were

reported between 07/23/05 - 10/26/05 (the faulty sensor

was replaced on 10/26/05). All of the incorrect TEMP/RH

values have since been corrected or marked as "missing".

: Station Maintenance (sm)

- Replaced Temperature/Relative Humidity Sensor (HMP45C).

- Replaced cable attached to wind vane.

: Station Online

- Data Collection and Data Archive for new station begins and

now made available via the MAWN website:

First data report: Jul 20, 2005 - 00:05 (Day=201)

: Station Maintenance (sm)

- Replaced Data Logger Battery.

- Collected Data Should Now Contain Complete Data Records.

Start Data Archive.

July 2005: New Station Installed:

Notes:

- leaf wetness B (canopy) - still needs to be installed.

- Data Logger Program Loaded: MAWN1C

Additional Station Needs:

- Data Logger Battery Does Not Hold Charge - Needs Replacement