Enviro-weather, formerly Michigan Automated Weather Network

msuhtrc — Maintenance Reports

Download maintenance log

: Station Maintenance [1145]

- routine site maintenance, including:

- checked anemomter (good)

- checked battery (14 V)

- checked leaf wetness [standard] sensor (good)*

- checked pyranometer (good)

- checked soil sensors (good)

- checked solar panel (20 V)

- checked tipping-bucket rain gauge (good)

- checked wind vane (properly aligned)

- cleaned atmp/relh sensor and radiation shield

- cleaned solar panel

* site does not include a canopy sensor

: Station Maintenance [1215]

- routine site maintenance, including:

- checked anemometer (bearings good)

- checked battery (13.42 V)

- checked solar panel (20.5 V)

- checked tipping-bucket rain gauge (good)

- tested leaf wetness sensor [standard] (good)

: Logger Maintenance [0005]

- replaced logger (CR1000 -> CR6)

- logger program: htc-bssdF.cr6*

* includes "maintenance mode"

: Station Maintenance [1615]

- replaced faulty atmp/relh sensor

: Station Maintenance [1055]

- routine station / site maintenance

: Station Maintenance [1350]

- annual station / site maintenance, including:

- replacement of leaf wetness sensor

: Station Maintenance [0006]

- loaded logger program "htc-bbaa"

: Station Maintenance [1515]

- annual maintenance, including:

- rewire of atmp/relh (HMP45C) to "continuous" power

: Station Maintenance [1500]

- reconnected 2" Soil Temp (SOIL0) sensor

: Station Maintenance [0930]

- replaced power supply

: System Maintenance [1645]

- battery voltage has stabilized - continue to monitor

- reactivated data updates

: Station Maintenance [0830]

- replaced SC932B interface

- installed solid-state relay

- replacement of 4" soil temperature sensor planned

for 12/20/2014

: Station Maintenance [1420]

- disconnected 4" soil temperature (soil1) sensor (possible

source of unintended power draw)

: Station Maintenance [1155]

- replaced failed logger battery

: System Maintenance [1306]

- moved data-collection to new LoggerNet server

- loaded logger program "mawn_abcf"

: Station Maintenance [1430]

- Replaced anemometer (wind speed)

: Station Maintenance [1500]

- Reinstalled all Soil Temperature and Soil Moisture

sensors. Cables were installed inside coduit.

- Relocated precipitation bucket... away from irrigation

influence.

: Station Maintenance [1600]

- Installed new 2" Soil Temperature Sensor [SOIL0]

- Installed new transmission cable between modem and

antenna

: Station Maintenance [0001]

- Loaded Logger Program - ABCF (hourly collection cycle)

: Station Maintenance [1728]

- Battery replacement. Weak battery has led to recent

data loss.

: Station Maintenance [1502]

- Loaded Logger Program "ABCW" (3-hour power/collection

cycle) due to battery/power troubles.

: Station Maintenance [1420]

- Replaced Logger Battery

: Loggernet Adjustment [0004]

- MAWN Program "ABCS" Loaded (30-minte power/collection

cycle).

: Data Quality [1100]

- Faulty soil temperature and soil moisture that was

recently introduced into the data archive for the

MSUHTRC was removed.

: Station Maintenance [1000]

- Replaced Soil Moisture Sensors

- Replaced Soil Temperature Sensors

(Note: troubles continue with soil temp data)

: Station Maintenance [1605]

- Replaced wireless broadband modem.

: Station Maintenance [1530]

- General station maintenance and system checks, including:

- Tipping-bucket rain gauge test.

: Station Maintenance

- General station maintenance and system checks, including:

- Soil Moisture sensors now installed vertically:

- MSTR 0: profile of depth = 0 - 12"

- MSTR 1: profile of depth = 12 - 24"

- Work was done approx: 1055 - 1115 (Day=157)

: Station Maintenance (jb)

- Loaded MAWN Program: MAWN_ABCF (1-hr power cycle) [13:37]

: Station Online

- Station added to MAWN web site.

: Data Collection Enabled

- Data Collection and Data Archive for new station begins:

First data report: May 03, 2007 - 00:05 (Day=123)

: Station Maintenance

- Established telecommunication between station cell-modem and

data collection PC/server on campus.

- Loaded MAWN Program: MAWN_ABCS

- Now able to collect raw weather data.

: New Station Installed

Notes:

Additional Station Needs:

- 2nd leaf wetness sensor