Enviro-weather, formerly Michigan Automated Weather Network

hudsonville — Maintenance Reports

Download maintenance log

: Station Maintenance [1100]

- routine site maintenance, including:

- checked soil sensor cables (good)

- checked wind vane (properly aligned)

- checked / tested battery (good)

- cleaned battery box

- cleaned hmp45c sensor and radiation shield (atmp/relh)

- cleaned / checked pyranometer

- cleaned / checked tipping-bucket rain gauge (adjusted level)

- cleaned / checked solar panel

- replaced anemometer (bad bearings)

- tested leaf wetness [standard] (good)*

* site does not make use of a canopy leaf wetness sensor

: Logger Maintenance [1204]

- loaded logger program: hvl-bbadC.cr1*

- no proper leaf wetness canopy

- wind direction fix

* supports "maintenance mode"

: Logger / Station Maintenance [1325]

- routine site maintenance

: Logger / Station Maintenance [1720]

- routine site maintenance

- updated modem

: Logger / Station Maintenance [1010]

- routine site maintenance

- updated modem

: Logger / Station Maintnenace [1400]

- loaded logger program: hvl-bbabC (237 -> LWS-L)*

* sensor replaced: 07/21/2020 (both)

- cleaned-up previously collected data

: Logger / Station Maintenance [1130]

- replaced leaf wetness (237 -> LWS-L) [both]

- requires logger program change

: Station Maintenance [1415]

- routine station maintenance

- replaced aneomometer

: Logger Maintenance [1115]

- replaced logger (was causing faulty pcpn)

: Logger Maintenance [1415]

- replaced faulty rain gauge

- replaced CR1000 logger wiring panel

: Logger Maintenance [1440]

- replaced logger (CR1000 -> CR1000)

- added PakBus modem

- loaded logger program: hvl-bbaaC

: Station Maintenance [1200]

- cleared tipping-bucket rain gauge obstruction

: Station Maintenance [1500]

- routine station / site maintenance

: Logger Maintenance [0002]

- loaded logger program "hvl-bbaaC"

: Station Maintenance [1545]

- annual station / site maintenance

: Station Maintenance [0930]

- Repaired and corrected power / charging issues

: Logger Maintenance [1422]

- loaded new logger program "hvl-bbaaC"

: Station Maintenance [1500]

- faulty logger replaced (CR10X - CR1000), including:

- verified HMP45C (atmp/relh) is connected to

continuous 12V power

: Station Maintenance; [1200]

- annual maintenance

: Station Maintenance [1100]

- loaded logger program: mawn_hvlf

- needed to support CS616 sensors

: Station Maintenance [1200]

- replaced faulty soil moisture sensors:

- CS615 -> CS616

: Station Maintenance [1315]

- annual maintenance

: Station Maintenance [1100]

- replaced faulty battery with 35Ah battery

: Station Maintenance [1140]

- replaced faulty battery

: Station Maintenance [1210]

- annual maintenance and weed removal

: Station Maintenance [1230]

- Site visit to correct HC2S3 (Air Temp/RH) wiring

- Reloaded logger program "mawn-hvlf"

: Station Maintenance [1200]

- Temp/RH troubles continue... replaced HMP45C sensor

with new HC2S3 sensor, but not properly reporting

data. Program change did not correct.

: Station Maintenance [1215]

- Temp/RH sensor replaced (HMP45C)

: System Maintenance [1304]

- moved data-collection to new LoggerNet server

- loaded logger program "mawn_hvlf"

: Station Maintenance [1710]

- routine maintenance

: Station Maintenance [1600]

- Replaced Air Temperature / Relative Humidity sensor

: Data Cleanup [1700]

- Using five-minute data, computed "hourly" and "daily"

preciptation that occurred during the following time

period:

03/03/2010 (d=062) - 06/03/2010 (d=154)

: Station Maintenance [1130]

- Repaired faulty leaf-wetness (i.e. standard mount was

covered with bird droppings).

- Cleaned canopy leaf-wetness sensor

- Following standard leaf wetness data was removed from

database:

05/26/10 (d=146) 00:05 - 06/09/10 (d=160) 11:25

- Following canopy leaf wetness data was removed from

database:

06/09/10 (d=160) 11:05 - 06/09/10 (d=160) 11:25

: Station Maintenance [0002]

- Loaded modified logger program to hopefully correct

faulty hourly/daily precip.

: Data Quality [1440]

- Placement of new sensor (atmp06in) was adjusted on

03/08/2010 (d=067) at 14:20. All "atmp06in" data

that was recorded prior to this date/time was

removed from the data archives.

: Station Maintenance [0005]

- Loaded Customized MAWN Program (MAWN_HVLF), which not

only powers the modem on an hourly schedule, but also

collects data from the following new sensor:

Air Temperature @ 06" height

Data from this new sensor is available in both "hourly"

and "daily" records, starting at the following time:

03/03/2010 (d=062) 00:05

: Data Correction [1100]

- Faulty Solar Radiation data that was introduced during

the following time period have been marked as "missing"

07/05/09 (d=186) 0900 - 07/10/09 (d=191) 1200

: Data Correction [1530]

- Anemometer was apparently not working properly during

the following time period:

08/07/09 (d=219) 1550 - 08/18/09 (d=230) 1515

All wind speed values reported during the time listed

above have been marked as "missing".

: Station Maintenance [1100]

- Faulty Solar Radiation Sensor was replaced.

: Station Maintenance [1400]

- General station maintenance and system checks, including:

- Tipping-bucket rain gauge test (faulty pcpn data

that was introduced was removed on 06/08/09)

: Station Maintenance

- Loaded MAWN Program - AACF (hourly power cycle) [0006]

: Station Maintenance

- Loaded MAWN Program - AACW (3-hour power cycle) [0002]

: Data Removal

- The Soil Temp B (4") sensor was replaced on 08/13/08. It

had been reporting faulty data since Jul 16, 2008. Therefore,

the 4" Soil Temperature data was removed from both the

archived raw data files as well as from the MAWN database

for the following time period:

07/16/08 (d=198) 21:00 - 08/13/08 (d=226) 11:00

: Station Maintenance

- General station maintenance and system checks, including:

- Soil Moisture sensors now installed vertically:

- MSTR 0: profile of depth = 0 - 12"

- MSTR 1: profile of depth = 12 - 24"

- Work was done approx: 11:00 - 1200 (Day=141)

: Data Management (jb)

- It was determined that several months of faulty solar

radiation data has existed in the archive for Hudsonville.

All solar radiation data between the following dates has

been removed:

Oct 01, 2006 [00:00] - May 16, 2007 [24:00]

: Station Maintenance (sm, bn)

- General station maintenance and system checks.

- solar radiation sensor was replaced.

- Work was done approx: 11:30 - 12:00 (Day=136)

: Station Maintenance (jb)

- Loaded MAWN Program: MAWN_AACF (00:05)

: Station Maintenance (bn)

- Troubleshooting random data outages at :05 and :35 past

the hour continues...

- Datalogger (CR10X) Replaced

- Loaded New MAWN Program: AACS (CS615, hourly voltage)

- Work was performed at: 1330 - 1415

: Station Maintenance (sm, bn)

- Random outages at :05 and :35 past the hour led to

an investigation of the Hudsonville MAWM station. The

Temp/RH sensor was covered with an insect nest. The

Temp/RH sensor and battery supply unit were replaced.

: Data Quality (jtb)

- Leaf Wetness A was found covered with bird droppings which

lead to faulty leaf wetness readings. The faulty data

appears to have started on Apr 07, 2006.

- Leaf Wetness A values have been marked as "missing" for the

following time period:

04/07/06 01:20 - 06/15/06 16:00

: Station Maintenance: (sm)

- Communication converted to broadband cell-modem:

- Broadband Cell modem installed.

- Datalogger Program "mawn_bacs" Loaded and Compiled

- Data Collection Configured To Upload Every 30 minutes.

- General Station Maintenance and System Checks:

- weed removal and application of Round-Up above soil temps

- sensor placement checked

- anemometer bearings checked

- rain gauge checked for debris

- leaf wetness 0 was found covered with bird droppings. The

sensor was cleaned.

- Work was done approx: 15:10 - 16:00 (Day=166)

: Station Maintenance (sm)

- General Station Maintenance and System Checks:

- weed removal and application of Round-Up above soil temps

- cleaned/checked all sensors

- approximate time of service: 12:20pm

: Station Maintenance: (crn, jal)

- Replaced Anemometer

- General Station Maintenance and System Checks:

- weed removal and application of Round-Up above soil temps

- tipping bucket rain gauge lid nearly clogged - debris was removed.

- tipping bucket rain gauge checked for accuracy

- Work was done approx: 17:00 - 17:30 (Day=217)

: Station Maintenance (crn, sm)

- Replaced Soil Temperature A (2"). The sensor

has been reporting bad data since 02/22/2004.

- Soil Temperature A (2") marked as "missing" in

the MAWN database for the following time period:

07/15/03 [00:05] - 05/04/04 [11:55]

: Maintenance

- Tipping bucket rain gauge was obstructed and was

unplugged around 8:30am by Dwayne Frens of the

Michigan Celery Cooperative.

- The five-minute precipitation total recorded at

08:35 and the hourly total reported at 09:00 are

therefore likely to be inflated.

- Manual precipitation observation taken at the

Michigan Celery Cooperative measured 2.78 inches

(storm total).

: Daylight Savings Time Adjustment.

- Daylight Savings Time Started on Day=97, Time=200.

- Time of Obs were modified by one hour (forward)

from Day=97, Time=200 through Day=97, Time=410.

: Daylight Savings Time Adjustment.

- Daylight Savings Time Ended on Day=301, Time=200.

- Time of Obs were modified by one hour (subtracted)

from Day=301, Time=200 through Day=301, Time=610.

: Phone Line Activated and Data Collection Started

Phone Number: (see setup notes)

- Archived data set should be setup to ensure that

the first day of record is complete. To do so,

use the following as the start of the the data

archive:

24 hour data: 24:00, Day=233 (08/21/2001)

60 min data: 01:00, Day=233 (08/21/2001)

05 min data: 00:05, Day=233 (08/21/2001)

: Datalogger Program (MAWN1B) Activated

Data Logger Start Times:

24 hour data: 24:00, Day=232 (08/20/2001)

60 min data: 10:00, Day=232 (08/20/2001)

05 min data: 09:35, Day=232 (08/20/2001)

: Station Installed