: Logger / Station Maintenance [1604]
- loaded logger program: kal-bbad.cr1* (237 -> LWS-L)**
* supports "maintenance mode"
** sensor replaced: 08/20/2020 (no canopy)
- cleaned-up previously collected data

- loaded logger program: kal-bbad.cr1* (237 -> LWS-L)**
* supports "maintenance mode"
** sensor replaced: 08/20/2020 (no canopy)
- cleaned-up previously collected data
- routine site maintenance, including:
- checked anemometer (good)
- checked battery (13.28 V)
- checked leaf wetness [standard] sensor (program update needed)*
- checked pyranometer (adjusted level)
- checked soil sensors (good)
- checked solar panel (20.54 V)
- checked tipping-bucket rain gauge (good)
- checked wind vane (properly aligned)
- cleaned atmp/relh sensor and radiation shield
- cleaned battery terminals
- cleaned solar panel
- weed removal
* site does not include a canopy sensor
- routine site maintenance, including:
- checked anemometer (bearings may be failing)
- checked battery (13.12 V)
- checked leaf wetness [standard] sensor (program update needed)*
- checked pyranometer (adjusted level)
- checked soil sensor cables (good)
- checked solar panel (14.49 V)
- checked tipping-bucket rain gauge (adjuste level)
- checked wind vane (properly aligned)
- cleaned atmp/relh sensor and radiation shield
- cleaned solar panel
- cleaned tipping-bucket rain gauge
* site does not include a canopy sensor
- routine site maintenance
- routine site maintenance, including:
- update modem
- routine maintenance, including:
- replaced leaf wetness (standard) sensor [237 -> LWS]*
- NOTE: updated logger program is needed
* site does not include a canopy sensor
- replaced charge controller
- replaced battery
- replaced logger (CR1000 -> CR1000)
- added PakBus modem
- loaded logger program: kal-bbaa
- annual station / site maintenance
- annual station / site maintenance
- routine maintenance
- loaded logger program "kal-bbab"
- annual maintenance
- replaced atmp/relh (HC2S3 -> HMP45C)
- atmp/relh now wired to "continuous" power
- Replaced faulty Air Temp/RH sensor
- Replaced faulty logger battery
- moved data-collection to new LoggerNet server
- loaded logger program "bbba-kal"
- Marked faulty Air Temperature data as "missing" during
the following time period:
02/03/2013 (d=034) 03:30 - 03/10/2013 (d=069) 18:20
- Faulty Air Temperature Sensor Replaced
- Station added to MAWN web site.
- Data Collection and Data Archive for new station begins:
First data report: Mar 22, 2012 - 00:05 (Day=088)
- Established telecommunication between station cell-modem
and data-collection PC/server on campus.
- Loaded MAWN Program: BBBA-KAL
B => CR1000/MI (Logger/State)
B => CS616 (Soil Moisture)
B => HC2S3 (Temp/RH)
A => 237 (Leaf Wetness)
KAL => Station ID (Kalkaska)
- Now able to collect raw weather data.