: Logger Maintenance [0005]
- replaced logger (CR1000 -> CR6)*
- logger program: kct-bssd.cr6**
* installed: 11/10/2023
* enabled: 11/15/2023
** includes leaf wetness upgrade (237 -> LWS) [no canaopy]
** includes soil sensor upgrade

- replaced logger (CR1000 -> CR6)*
- logger program: kct-bssd.cr6**
* installed: 11/10/2023
* enabled: 11/15/2023
** includes leaf wetness upgrade (237 -> LWS) [no canaopy]
** includes soil sensor upgrade
- routine site maintenance, including:
- checked anemometer (good)
- checked battery (13.32 V)
- checked leaf wetness [canopy] sensor (not in canopy)
- checked leaf wetness [standard] sensor (ok)
- checked pyranometer (adjusted level)
- checked soil sensors (good)
- checked solar panel (20.0 V)
- checked tipping-bucket rain gauge (adjusted level)
- checked wind vane (properly aligned)
- cleaned atmp/relh sensor and radiation shield
- cleaned battery box
- cleaned battery terminals
- cleaned solar panel
- weed removal
- routine site mainteance, inluding:
- checked anemometer (good)
- checked battery (13.79 V)
- checked leaf wetenss [canopy] sensor*
- checked leaf wetness [standard] sensor (good)
- checked pyranometer (adjusted level)
- checked soil sensors (good)
- checked solar panel (20.34 V)
- checked tipping-bucket rain gauge (adjusted level)
- checked wind vane (properly aligned)
- cleaned atmp/relh sensor and radiation shield
- cleaned battery terminals
- cleaned solar panel
- weed removal
* canopy sensor mounted on station tripod... not in a canopy
- routine site maintenance, including:
- checked anemometer (good)
- checked battery (13.67 V)
- checked leaf wetness [standard] sensor: (good)*
- checked pyranometer (adjusted level)
- checked soil sensors (good)
- checked solar panel (19.82 V)
- checked tipping-bucket rain guage (adjusted level)
- checked wind vane (properly aligned)
- cleaned atmp/relh sensor and radiation sheild
- cleaned solar panel
* canopy sensor mounted on station tripod... not in a canopy
- routine site maintenance, including:
- checked anemometer (bearings good)
- checked battery
- checked pyranometer (adjusted level)
- checked wind vane (properly aligned)
- checked / cleaned solar panel
- checked / tested leaf wetness (canopy.. good)*
- checked / tested leaf wetness (standard... good)
- cleaned battery box
- cleaned tipping-bucket rain gauge
- weed / grass removal
* canopy sensor mounted on station tripod... not in a canopy
- routine site maintenance
- routine site maintenance, including:
- modem update
- replaced logger (CR1000 -> CR1000)
- loaded logger program: kct-bbaa
- routine site maintenance, including:
- replaced soil moisture sensor (sensor 0)
- replaced logger (CR1000 -> CR1000)
- added PakBus modem
- loaded logger program: kct-bbaa
- replaced communication modem
- general maintenance / weed removal
- annual station / site maintenance
- loaded logger program "kct-bbaa"
- annual maintenance
- annual maintenance, including:
- rewire of atmp/relh (HMP45C) to "continuous" power
- replaced soil temperature sensors
- loaded temporary logger program (1210)
- reload logger program: bbaa-kct (1501)
- replaced logger battery
- cleared ice/snow off of solar panel
- routine maintenance, including:
- replacement of anemometer (wind speed)
- Routine maintenance
- cleaned temp/rh sensor
- moved configuration to new LoggerNet server
- loaded logger program "bbaa-kct"
- replaced logger battery
- replaced logger battery
- replaced faulty wireless modem
- Station added to MAWN web site.
- Data Collection and Data Archive for new station begins:
First data report: Nov 10, 2009 - 00:05 (Day=314)
- Station Installed at Field Location.
- Established telecommunication between station cell-modem and
data collection PC/server on campus.
- Loaded MAWN Program: BBC-KCT
B => CR1000
B => CS616
C => Broadband Cell Modem (IP)
KCT => Station ID (Kent City)
- Now able to collect raw weather data.
- Station Communication (Broadband Modem) Installed
and Configured.