: Logger / Station Maintenance [1505]
- loaded logger program: mct-bbad.cr1* (237 -> LWS-L)**
* supports "maintenance mode"
** sensor replaced: 07/30/2020 (no canopy)
- cleaned-up previously collected data

- loaded logger program: mct-bbad.cr1* (237 -> LWS-L)**
* supports "maintenance mode"
** sensor replaced: 07/30/2020 (no canopy)
- cleaned-up previously collected data
- routine site maintenance, including:
- checked anemometer (bearings good)
- checked leaf wetness sensors*
- checked pyranometer (good condition, level)
- checked soil sensor cables (good)
- checked wind vane (properly aligned)
- checked / cleaned solar panel (19.39 V)
- checked / cleaned tipping-bucket rain gauge
- checked / tested battery (13.16 V)
- cleaned battery box
- cleaned grounding rod
- cleaned radiation shield / RH sensor (hmp45c)
- weed removal
* logger program requires update
* site does not include a canopy sensor
- routine site maintenance, including:
- checked anemometer (bearings good)
- checked battery box (clean)
- checked leaf wetness sensors*
- checked pyranometer (good condition, level)
- checked soil sensor cables (good)
- checked wind vane (properly aligned)
- checked / cleaned solar panel
- checked / cleaned tipping-bucket rain gauge
- checked / tested battery (13.25 V)
- weed removal
* logger program requires update
* site does not include a canopy sensor
- routine site maintenance
- routine site maintenance
- routine site maintenance, including:
- replacement of 5cm soil temperature (soil0) sensor
- reinstallation of both soil temp sensors (5cm, 10cm)
- installed additional battery
- updated modem
- upgraded power (battery)
- replaced logger (CR1000 -> CR1000)
- added PakBus modem
- loaded logger program: mct-bbaa
- repair tipping-bucket rain gauge (cleared obstruction)
- repair faulty atmp/relh sensor
- annual maintenance
- annual maintenance, including:
- replacement of faulty soil temperature sensors
- routine maintenance
- precipitation bucket check
- loaded logger program "mct-bbaa"
- annual maintenance
- rewired air temp/relh (HMP45C) to "continuous" power
- annual maintenance and weed removal
- annual maintenance and weed removal
- replaced weak battery
- installation of tipping-bucket rain gauge was corrected
as it was "severely out of level".
- moved data-collection to new LoggerNet server
- loaded logger program "bbba-mct"
- routine maintenance, including:
- replacement of pyranomter (solar radiation)
- Replaced faulty AIR TEMP/RH sensor
- Repaired / Replaced Faulty Soil Temperature Sensors.
- Due to faulty sensor, data marked as "missing" for Soil
Temperature 1 (4") for following time period:
01/30/2013 (d=030) 06:30 - 05/02/2013 (d=122) 12:30
- Rain gauge unplugged. Due to blockage, precipiation
data has been marked as "missing" for the following
time period:
07/25/2012 (d=207) 00:00 - 08/20/2012 (d=233) 13:00
- Station added to MAWN web site.
- Data Collection and Data Archive for new station begins:
First data report: Mar 22, 2012 - 00:05 (Day=088)
- TEMP/RH Sensor repaired (incorrect wiring)
- Noted troubles with TEMP/RH Sensor
- Established telecommunication between station cell-modem
and data-collection PC/server on campus.
- Loaded MAWN Program: BBBA-MCT
B => CR1000/MI (Logger/State)
B => CS616 (Soil Moisture)
B => HC2S3 (Temp/RH)
A => 237 (Leaf Wetness)
MCT => Station ID (Mecosta)
- Now able to collect raw weather data.