Enviro-weather, formerly Michigan Automated Weather Network

stephenson — Maintenance Reports

Download maintenance log

: Station Maintenance [1035]

- routine site maintenance, including:

- checked atmp/relh (cleaned sensor)

- checked leaf wetness [standard] (good)*

- checked pyranometer (good)

- checked solar panel (adjusted angle)

- checked tipping-bucket rain gauge (adjust level)

- checked voltages: battery (13.47V), solar panel (19.41V)

- checked wind speed / direction (good)

- cleaned pyranometer

- cleaned radiation shield (atmp/relh)

- cleaned solar panel

- cleaned tipping-bucket rain gauge

- updated cell modem OS

- weed removal

* site does not include a canopy sensor

: Logger Maintenance [1404]

- loaded logger program: stv-bbad.cr1 (237 -> LWS-L)*

* supports "maintenance mode"

* sensor replaced: 03/22/2024

* cleaned-up previously collected data

: Station Maintenance [1525]

- routine site maintenance, including:

- checked atmp/relh (good)

- checked batteries:

- replaced 35Ah battery (mouse issues)

- current 7Ah battery is fine

- checked soil sensors (good)

- checked station tripod (adjusted level)

- checked tipping-bucket rain gauge (added funnel screen)

- cleaned radiation shield (atmp/relh)

- replaced leaf wetness [standard] (237 -> LWS)* **

- replaced wind sentry (i.e. direction / speed)

- weed removal

* site does not include a canopy sensor

** an updated logger program is needed

: Logger / Station Maintenance [1240]

- site visit, including:

- tipping-bucket rain gauge repair (adjusted mounting)

- installed updated modem

: Logger / Station Maintenance [1100]

- cleaned tipping-bucket rain gauge (cleared obstruction)

: Logger / Station Maintenance [1100]

- replaced logger (CR10X -> CR1000)

- added PakBus modem

- loaded logger program: stv-bbac

: Station Maintenance [1000]

- repaired tipping-bucket precipitation issue:

- unplugged funnel

: Station Maintenance [1100]

- unclogged precipitation bucket

: Station Maintenance [1330]

- replaced faulty battery

: Station Maintenance [1505]

- Moved data-collection to new LoggerNet server

- Loaded logger program: ABCF (hourly cycle)

: Station Maintenance [0730]

- Battery replaced

: Station Maintnenace

- Battery replaced

: Station Maintenance [0930]

- Replace wireless broadband modem

: Station Maintenance [0001]

- Loaded MAWN Program - ABCF (hourly collection cycle)

: Station Maintenance [0900]

- Telecommunication issues resolved last Friday. Checked

data and reactived "live" updates this morning. Unfortunately,

data for the following time period was lost:

12/14/2010 (d=348) 06:05 - 12/20/2010 (d=354) 15:00

: Station Maintenance [0002]

- Loaded MAWN Program - ABCW (3-hour collection cycle)

: Station Maintenance [1000]

- Weak battery recently detected... replaced with a new

battery this morning.

: Station Maintenance [1100]

- Routine maintence, including:

- checked/reinstalled 4" soil temp sensor

: Station Maintenance [1250]

- Replaced short-haul modem/FTP with wireless broadband.

- Loaded MAWN Program ABCS (30-minute power cycle)

- Added "battery voltage" to hourly data table

: Station Update

- Network connection at Stephenson has been repaired. Station

is back online.

: Station Update

- Recent thunderstorm has knocked-out internet connectivity

at the Stephenson station. The network at Stephenson

should be back up later in the week or early next week.

: Station Maintenance (sm, jb)

- Recent telecommunication troubles that prevented proper

data collection has been repaired. Data is once again

being collected and updated to the MAWN database.

- Due to the telecommunication outage, data for the following

time period has been lost:

03/19/07 (Day=78) 08:35 CDT - 04/28/07 (Day=118) 17:50 CDT

: Station Maintenance (sm)

- Communications between the data-collection PC and the

data-logger on the weather station had been out for

several weeks. Replacement of the short-haul modem

components corrected the trouble. Unfortunately,

uncollected data was lost for the following time

period:

10/04/05 (Day=277) 18:35 CDT - 10/16/05 (Day=289) 16:30 CDT

: Data Quality Note

- It was determined that the clock on the Stephenson MAWN

station slowly drifted and was reporting incorrectly for

most of the winter. Because of the incorrect clock, the

observation times of the data reports are in error.

- The clock was corrected on 04/10/2005.

- Prior to the correction (Nov 2004 - April 09, 2005), the

observation times may be off by several hours. Eventually,

all data with incorrect time stamps will either be corrected

or removed from the MAWN database.

: Spring Maintenance (crn)

- Site visit - Sensor Check: All OK

: Data Collection and Data Archive for new station begins

First report: Sep 30, 2003 - 00:05 (Day=273)

: New Station Installed

Notes:

- leaf wetness B (canopy) - not installed

- pressure sensor installed - not active

- Soil Moisture Sensor Type - CS616 Water Content

Reflectometer

- Data Logger Program Loaded: MAWN1C

Additional Station Needs: