williamsburg20 — Maintenance Reports
Download maintenance log
: Station Maintenance [1330]
- routine station maintenance, including:
- checked anemometer (bearings good)
- checked battery (13.64 V)
- checked soil sensor cables (good)
- checked solar panel (14.10 V)
- cleaned battery box
- replaced leaf wetness sensor [standard]*
- replaced tipping-bucket rain gauge
* there is no canopy sensor at this site
: Station Maintenance [1655]
- routine site maintenance, including:
- checked anemometer (bearings good)
- checked battery (13.24 V)
- checked pyranometer (cleaaned, adjusted level)
- checked soil sensor cables (good)
- checked solar panel (21.95 V)
- checked tipping-bucket rain gauge (adjusted level)
- checked wind vane (properly aligned)
- cleaned atmp/relh sensor and radiation shield [1.5m]
- cleaned solar panel
- tested leaf wetness [standard] (good)*
* there is no canopy sensor at this site
: Station Maintenance [1635]
- routine site maintenance, including:
- checked anemometer (bearings good)
- checked battery (13.6 V)
- checked pyranometer (adjusted level)
- checked soil sensor cables (good)
- checked solar panel (14.3 V)
- checked tipping-bucket rain gauge (cleaned, leveled)
- checked wind vane (properly aligned)
- cleaned atmp/relh sensors and radiation shields [10cm, 1.5m]
- cleaned solar panel
- removed leaf wetness [canopy] (not installed in canopy)
- tested leaf wetness [standard] (good)*
- weed removal
: Station Maintenance [1500]
- routine site maintenance, including:
- repair tipping-bucket rain gauge
NOTE: canopy sensor is not install within a canopy
: Station Maintenance [1230]
- routine site maintenance
: Station Maintenance [1225]
- replaced modem
: Station Maintenance [1630]
- Corrected tipping-bucket rain gauge installation / mount
: Logger / Station Maintenance [1410]
- routine maintenance
- replaced battery cable
: Logger Maintenance [1811]
- logger was manually reset (communication issue)
: Logger / Station Maintenance [1310]
- replaced logger (CR3000 -> CR3000)
- added PakBus modem
- loaded logger program: wmt-bbcbT
: Station Maintenance [1400]
- Repaired "20m Air Temperature" sensor
: Data Archive Reset: [----]
- Reset Start of Data Archive:
First data report: April 23, 2017 (Day=113) 00:00
: Station Maintenance: [----]
- complete sensor installation
: LoggerNet Adjustment [1045]
- changed data-collection to 5-minutes (from 15-minutes)
xx/xx/xxx: Station Online: [xxxx]
- Station added to Enviroweather/MAWN Web Site
: Data Archive Reset: [----]
- Reset Start of Data Archive:
First data report: XXX XX. XXXX (Day=XXX) XX;XX ????
: Data Collection Enabled [1800]
- Data Collection and Data Archive for new station begins:
First data report: March 07, 2017 (Day=066) 00:00 ????
: Station Setup [1730]
- Loaded MAWN Program: WMT-BBCBT
WMT => Station ID (Williamsburg 20m tower)
B => CR1000/MI (Logger/State)
B => CS616 (Soil Moisture)
C => HMP155A (Temp/RH)
B => LWS-L (Leaf Wetness)
T => 20m Tower Station
- Now able to collect raw weather data.