Download maintenance log

: Station Maintenance [1330]

- routine station maintenance, including:

- checked anemometer (bearings good)

- checked battery (13.64 V)

- checked soil sensor cables (good)

- checked solar panel (14.10 V)

- cleaned battery box

- replaced leaf wetness sensor [standard]*

- replaced tipping-bucket rain gauge

* there is no canopy sensor at this site

: Station Maintenance [1655]

- routine site maintenance, including:

- checked anemometer (bearings good)

- checked battery (13.24 V)

- checked pyranometer (cleaaned, adjusted level)

- checked soil sensor cables (good)

- checked solar panel (21.95 V)

- checked tipping-bucket rain gauge (adjusted level)

- checked wind vane (properly aligned)

- cleaned atmp/relh sensor and radiation shield [1.5m]

- cleaned solar panel

- tested leaf wetness [standard] (good)*

* there is no canopy sensor at this site

: Station Maintenance [1635]

- routine site maintenance, including:

- checked anemometer (bearings good)

- checked battery (13.6 V)

- checked pyranometer (adjusted level)

- checked soil sensor cables (good)

- checked solar panel (14.3 V)

- checked tipping-bucket rain gauge (cleaned, leveled)

- checked wind vane (properly aligned)

- cleaned atmp/relh sensors and radiation shields [10cm, 1.5m]

- cleaned solar panel

- removed leaf wetness [canopy] (not installed in canopy)

- tested leaf wetness [standard] (good)*

- weed removal

: Station Maintenance [1500]

- routine site maintenance, including:

- repair tipping-bucket rain gauge

NOTE: canopy sensor is not install within a canopy

: Station Maintenance [1230]

- routine site maintenance

: Station Maintenance [1225]

- replaced modem

: Station Maintenance [1630]

- Corrected tipping-bucket rain gauge installation / mount

: Logger / Station Maintenance [1410]

- routine maintenance

- replaced battery cable

: Logger Maintenance [1811]

- logger was manually reset (communication issue)

: Logger / Station Maintenance [1310]

- replaced logger (CR3000 -> CR3000)

- added PakBus modem

- loaded logger program: wmt-bbcbT

: Station Maintenance [1400]

- Repaired "20m Air Temperature" sensor

: Data Archive Reset: [----]

- Reset Start of Data Archive:

First data report: April 23, 2017 (Day=113) 00:00

: Station Maintenance: [----]

- complete sensor installation

: LoggerNet Adjustment [1045]

- changed data-collection to 5-minutes (from 15-minutes)

xx/xx/xxx: Station Online: [xxxx]

- Station added to Enviroweather/MAWN Web Site

: Data Archive Reset: [----]

- Reset Start of Data Archive:

First data report: XXX XX. XXXX (Day=XXX) XX;XX ????

: Data Collection Enabled [1800]

- Data Collection and Data Archive for new station begins:

First data report: March 07, 2017 (Day=066) 00:00 ????

: Station Setup [1730]

- Loaded MAWN Program: WMT-BBCBT

WMT => Station ID (Williamsburg 20m tower)

B => CR1000/MI (Logger/State)

B => CS616 (Soil Moisture)

C => HMP155A (Temp/RH)

B => LWS-L (Leaf Wetness)

T => 20m Tower Station

- Now able to collect raw weather data.