aetna — Maintenance Reports
Download maintenance log
: Station Maintenance [1330]
- site maintenance, including:
- checked anemometer (bearings good)
- checked battery (13.5 V)
- checked soil sensor and power cables (good)
- checked solar panel (22.3 V)
- checked tipping-bucket rain gauge (good)
- checked wind vane (properly aligned)
- cleaned atmp/relh sensor and radiation shield
- tested leaf wetness sensor [standard] (good)*
- replaced pyranometer
* site does not include a canopy sensor
: Station Maintenance [1110]
- routine site maintenance, including
- checked anemometer (bearings good)
- checked battery (13.32 V)
- checked pyranometer (good)
- checked soil sensor cables (good)
- checked solar panel (20.31 V)
- checked tipping-bucket rain gauge
- checked wind vane (properly aligned)
- checked / tested leaf wetness sensor [standard] (good)*
- cleaned atmp/relh sensor and radiation shield
- cleaned battery box
- weed removal
* site does not include a canopy sensor
: Station Maintenance [1030]
- routine site maintenance, including:
- checked anemometer (bearings good)
- checked pyranometer (adjusted mount / level)
- checked soil sensor cables (good)
- checked wind vane (properly aligned)
- checked / cleaned solar panel
- checked / cleaned tipping-bucket rain gauge
- checked / tested battery
- cleaned battery box
- replaced faulty leaf wetness sensor [standard mount]*
- weed removal
* site does not include a canopy sensor
: Station Maintenance [1110]
- routine site maintenance
: Station / Logger Maintenance [1150]
- routine site maintenance
- modem upgrade
- replaced soil temperature / moisture sensor [10cm]
: Station Maintenance [1520]
- replaced fault soil temp/soil moisture sensor [10cm]
: Station / Logger Maintenance [1145]
- repaired power issues
: Station Maintenance [1130]
- routine station maintenance
- installed new leaf wetness mount
- soil sensor wiring (power) adjustment
: Station Maintenance [1510]
- repaired atmp/relh/dwpt sensor
: Station Maintenance [1245]
- install soil sensors (i.e. soil temp/moisture)
: Station Online [1100]
- Station added to Enviroweather/MAWN database system
: Data Collection Enabled [1110]
- Data Collection and Data Archive for new station begins:
First data report: April 10, 2019 (d=100) 00:05
: Logger Setup [1110]
- Loaded MAWN Program: aet-bssd
aet => Station ID (aetna)
b => CR1000/MI (Logger/Site)
s => SDI-12 [CS650] (Soil Moisture)
s => SDI-12 [HygroVue10] (Temp/RH)
d => LWS-L (Leaf Wetness) [no canopy]
- Now able to collect raw weather data.
: Station Maintenance: [----]
- Established telecommunication between station cell-modem
and data-collection PC/server on campus.
: Station Setup [----]
- station setup/activated at field site