: Station Maintenance [0915]
- logger repair / communications troubleshooting:
- replaced logger (CR1000 -> CR1000)

- logger repair / communications troubleshooting:
- replaced logger (CR1000 -> CR1000)
- logger repair / communications troubleshooting:
- replaced charge controller
- replaced 12V switch
- replaced modem
* return visit needed to replace logger
- replaced faulty leaf wetness sensor [standard]
- routine site maintenance, including:
- checked anemometer (good)
- checked battery box
- checked leaf wetness [standard] (needs replacement)*
- checked soil sensor cables (good)
- checked tipping-bucket rain gauge (adjusted level)
- cleaned atmp/relh radiation shield
- cleaned solar panel
- replaced battery
* site does not include a canopy sensor
- routine site maintenance, including:
- checked battery (13.16 V)
- checked pyranometer (good)
- checked soil sensor cables (good)
- checked solar panel (20.12 V)
- checked / tested leaf wetness [standard] (good)*
- checked / tested tipping-bucket rain gauge (good)
- cleaned atmp/relh sensor and radiation shield
- cleaned battery box
- cleaned solar panel
- replaced anemometer
- replaced wind vane
- weed removal
* site does not include a canopy sensor
- routine site maintenance, including:
- checked anemometer (fair... replace soon)
- checked battery (13.52 V)
- checked leaf wetness [standard] (good)*
- checked pyranometer (good)
- checked soil sensor cables (good)
- checked solar panel (19.28 V)
- checked tipping-bucket rain gauge
- checked wind vane (properly aligned)
- cleaned atmp/relh sensor and radiation shield
- cleaned battery box
* site does not include a canopy sensor
- loaded logger program: les-bbad.cr1* (237 -> LWS-L)**
* supports "maintenance mode"
** sensor replaced: 07/08/2020 (no canopy)
- cleaned-up previously collected data
- routine site maintenance
- routine site maintenance, including...
...modem replacement
- routine site maintenance, including...
...reinstall "mstr0" (00-30cm soil moisture) sensor
...replace "soil0" (05cm soil temperature) sensor
...replace "soil1" (10cm soil temperature) sensor
- routine site maintenace, including...
...installation of new 35amp battery / charge controller
- replaced logger (CR1000 -> CR1000)
- added PakBus modem
- loaded logger program: les-bbaa
- logger replaced (due to lithium battery issues)
- reloaded original logger program (les-bbaa)
- annual maintenance
- loaded logger program "les-bbaa"
- annual maintenace
- annual maintenance, including:
- rewire of atmp/relh (HMP45C) to "continuous" power
- replaced logger (CR1000 -> CR1000)
- replaced rain gauge
- annual maintenance and weed removal
- leveled precipitation bucket
- annual maintenance and weed removal
- cleaned leaf wetness sensors
- routine station maintenance
- replaced soil moisture (mstr0) sensor
- moved data-collection to new LoggerNet server
- loaded logger program "bbaa-les"
- Replaced Soil Temperature and Soil Moisture sensors
(cables leading to sensors were cut)
- routine annual maintenance
- Replaced Soil Temp 0 (2") Sensor
- Reinstalled both Soil Temperature Sensors
- Leaf Wetness 0 (Standard Mount) was replaced
- Leaf Wetness 1 (Canopy) was cleaned.
- Replaced Modem
- General station maintenance (weed control, sensor checks)
- Replaced Wireless Broadband (Cell-IP) Modem [11:20]
- Station added to MAWN web site.
- Data Collection and Data Archive for new station begins:
First data report: Aug 14, 2008 - 00:05 (Day=227)
- Established telecommunication between station cell-modem and
data collection PC/server on campus.
- Loaded MAWN Program: BBC-LES
B => CR1000
B => CS616
C => Broadband Cell Modem (IP)
LES => Station ID (Leslie)
- Now able to collect raw weather data.