Enviro-weather, formerly Michigan Automated Weather Network

reeman — Maintenance Reports

Download maintenance log

: Station Maintenance [1120]

- routine site maintenance, including:

- checked battery (13.67 V)

- checked power and sensor cables, clean connnections

- checked solar panel (22.6 V)

- checked wind vane (properly aligned)

- tested leaf-wetness sensor [standard] (fair)* **

- tested pyranometer (good)

- tested tipping-bucket rain gauge

- replaced anemometer

- replaced hygrovue10 (atmp/relh/dwpt)

* canopy sensor is not used at this site

** may need to replace standard leaf wetness during next visit

: Station Maintenance [1145]

- routine site maintenance, including:

- checked anemometer (good)

- checked battery (13.51 V)

- check soil sensor cables (good)

- checked solar panel (21.6 V)

- checked tipping-bucket rain gauge (level)

- checked wind vane (properly aligned)

- cleaned atmp/relh sensor and radiation shield

- cleaned battery box**

- cleaned solar panel

- removed leaf wetness sensor [canopy]

- replaced hygrovue 10 (atmp/relh/dwpt)

- replaced pyranometer

- tested leaf wetness sensor [standard] (good)*

- tested tipping-bucket rain gauge (good)

- weed removal

* canopy sensor is not installed in a canopy at this site

** battery cable may need to be replaced during next site visit

: Station Maintenance [1210]

- routine site maintenance, including:

- checked anemometer (bearings good)

- checked battery (may need new cables next visit)

- checked pyranometer (good)

- checked soil sensor cables

- checked wind vane (proplerly aligned)

- checked / tested leaf wetness [standard] (good)*

- checked / cleaned solar panel

- checked / cleaned tipping-bucket rain gauge (adjusted level)

- cleaned atmp/relh sensor and radiation shield

- cleaned battery box

- weed removal

* canopy sensor is attached to tripod leg... not in actual canopy

: Station Maintenance [1040]

- routine site maintenance

: Station Maintenance [1110]

- routine site maintenance

: Logger Maintenance [0915]

- replaced modem (modem OS update)

- reset logger

: Logger Maintenance [0845]

- reset logger/modem (communication issues)

: Logger Maintenance [0955]

- reset logger/modem (communication issues)

: Station Maintenance [1250]

- routine station maintenance

- installed new leaf wetness mount

: Station Maintenance [1230]

- install soil sensors (i.e. soil temp/moisture)

: Station Online: [----]

- Station added to Enviroweather/MAWN database system

: Data Collection Enabled [1450]

- Data Collection and Data Archive for new station begins:

First data report: March 23, 2019 (d=082) 00:05

: Logger Setup [1445]

- Loaded MAWN Program: rfw-bssd

rfw => Station ID (conklin)

b => CR1000/MI (Logger/Site)

s => SDI-12 [CS650] (Soil Moisture)

s => SDI-12 [HygroVue10] (Temp/RH)

d => LWS-L (Leaf Wetness) [no canopy]

- Now able to collect raw weather data.

: Station Maintenance: [----]

- Established telecommunication between station cell-modem

and data-collection PC/server on campus.

: Station Setup [----]

- station setup/activated at field site