: Logger Maintenance [1049]
- loaded logger program: drf-bbsdS.cr1*
* supports HMP155A -> HygroVue10 change (atmp/relh)

- loaded logger program: drf-bbsdS.cr1*
* supports HMP155A -> HygroVue10 change (atmp/relh)
- resolved communication issue:
- reconnected ground wire
- replaced modem
- routine site maintenance, including:
- checked anemometer (bearings good)
- checked leaf wetness sensor [standard mount]*
- checked pyranometer
- checked soil moisture sensors (installed vertically)
- checked soil temperature senosors (orientation unknown)
- checked wind vane (properly aligned)
- checked / cleaned atmp/relh sensors (45cm, 1.5m, 3m)
- checked / cleaned battery (14.5V)
- checked / cleaned solar panel (over 20V)
- checked / cleaned tipping-bucket raing gauge (adjusted level)
* site does not include a canopy sensor
- checked battery and charging system (good)
- replaced modem*
* communication issues not resolved
- routine site maintenance, including:
- checked anemometer (bearings good)
- checked leaf wetness sensor [standard mount]*
- checked pyranometer (good, no adjustments needed)
- checked soil sensor cables (good)
- checked wind vane (properly aligned)
- checked / cleaned tipping-bucket rain gauge
- checked / cleaned battery (13.03 V)
- checked / cleaned solar panel (20.16 V)
- cleaned battery box
- cleaned radiation shield on ATMP/RELH sensor
- site well-maintained, no weed removal needed
* site does not included a canopy sensor
- routine site maintenance, including:
- checked anemometer (good)
- checked leaf wetness sensor [standard mount]*
- checked pyranometer (good)
- checked soil sensors (adjusted install of soil moisture)
- checked soil sensor cables (good)
- checked wind vane (properly aligned)
- checked / cleaned tipping-bucket rain gauge
- checked / tested battery (13.23 V)
- checked / tested solar panel (20.56 V)
- cleaned battery box
- site well-maintained, no weed removal needed
* site does not included a canopy sensor
- loaded logger program: drf-bbcdS.cr1*
- no canopy leaf wetness sensor
* supports "maintenance mode"
- routine site maintenance
- replaced faulty atmp/relh (hmp155a) sensor
- routine site maintenance
- upgraded cell modem
- reinstalled 5cm soul temp sensor (soil0)
- replaced logger (CR1000 -> CR1000)
- logger program "drf-bbcdS" started
06/07.2020: Logger / Station Maintenance: [1130]
- replace wireless modem
- added antenna
- checked power supply
- routine maintenance
- replaced logger (CR1000 -> CR1000)
- added PakBus modem
- loaded logger program: drf-bbcdS
- replaced logger (CR1000 -> CR1000) [failed]
- postpone PakBus modem upgrade
- annual station / site maintenance
- loaded logger program "drf-bbcdS"
- loaded logger program "drf-bbcdS"
- loaded updated logged program "drf-bbcbS":
- program modified to mask-out all canopy leaf
wetness (lws1) data. If sensor is ever installed
within a representative canopy, logger program will
need to be modified.
- Soybean Inversion Study Upgrade, including:
- replace ATMP/RELH sensor @ 1.5m (HMP45C -> HMP155A)
- install new ATMP/RELH sensor @ 45cm
- install new ATMP/RELH sensor @ 3m
- load new logger program "drf-bbcbS"
- annual maintenance
- loaded logger program "drf-bbab"
- annual maintenance
- replaced atmp/relh (HC2S3 -> HMP45C)
- atmp/relh now wired to "continuous" power
- Station added to Enviroweather/MAWN Web Site
- Data Collection and Data Archive for new station begins:
First data report: September 01, 2015 (Day=244) 00:05
- Established telecommunication between station cell-modem
and data-collection PC/server on campus.
- Loaded MAWN Program: DRF-BBBB
DRF => Station ID (Deerfield)
B => CR1000/MI (Logger/State)
B => CS616 (Soil Moisture)
B => HC2S3 (Temp/RH)
B => LWS-L (Leaf Wetness)
- Now able to collect raw weather data.
- Station installed at station field site